Hirschmann iVISOR mentor QVGA Service Manual

Hirschmann iVISOR mentor QVGA Service Manual

Hide thumbs Also See for iVISOR mentor QVGA:

Advertisement

iVISOR
mentor QVGA
Service Manual
Edition 2/2009 Rev. A
The order code for this document is
24 183 69 1012e (Generic)
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com
24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Contents
General information
Important notes
Service menus
Troubleshooting
Appendix:
Wiring Diagrams ...
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iVISOR mentor QVGA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hirschmann iVISOR mentor QVGA

  • Page 1 The order code for this document is 24 183 69 1012e (Generic) © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 2: Table Of Contents

    Appendix: Wiring, Drawings, Spare Parts The manufacturer reserves the right to modify the contents of this manual without notice. Hirschmann will not be liable for errors contained in this manual or for incidental or consequential damages in connection with the furnishing, performance, or use of this manual.
  • Page 3: General Information

    The system components are connected via CAN bus. Components of the iVISOR mentor QVGA LMI system © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 4 Slew Angle Sensor: The gSENS DWG sensor converts the circular motion of the upper structure of the crane into a CAN signal. © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 5: Important Notes

    © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 6: Sensor Calibration

    If an invalid service code is entered, you are prompted to enter it again or to abort the input. 57595 © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 7 3.3) boom length 3.4) boom angle signal piston side signal signal signal © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 8: Zero-Setting The Pressure Signals

    / go to next menu © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 9 / go to next menu © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 10: Zero-Setting The Slewing Signal

    180° position skip calibration step / go to next menu © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 11: Length Sensor Calibration Procedure

    • If it is not, adjust length potentiometer mechanically as described below: © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 12 / go to next menu Afterward next calibration screen appears: © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 13 • Check whether boom is fully extended, then press "OK". Afterward next calibration step (angle) appears. © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 14: Angle Sensor Calibration Procedure

    / go to next menu © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 15 / go to next menu © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 16 • Now repeat procedure as shown for the boom angle 65° and 75°. If values were modified a confirmation screen appears at the end: © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 17 Press ESC to leave sensor adjustments and return to normal LMI screen. © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 18: Troubleshooting

    If faults occur, please contact Hirschmann Service USA: www.hirschmann.com > USA > Electronic Control Systems > Contact - ECS. © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 19: Error Code List

    Electronic component in the Replace sensor unit boom" measuring channel is defective © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 20 • • Angle potentiometer defective Replace angle sensor Fallen below lower limit © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 21 Error in the system defective. program • • Flash-EPROM defective Replace central unit © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 22 Can bus port in the central unit Replace the central unit defective © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 23 Connect or replace cable to the (not with radio A2B) switch A2B switch © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
  • Page 24 NOTE: If an error message not included in the above list is displayed, please contact Hirschmann Service USA: www.hirschmann.com > USA > Electronic Control Systems > Contact - ECS. © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com...
  • Page 25: Revision History

    LSQN V 1.11 (20090223) Graphics V 1.00 Application MQVGA V 1.00 (20090220) © 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.

Table of Contents