DIP 3 in ON position
Giving a negative (0V) to terminal no. 5, all LEDs of the flashing unit flash 3 times (ON). Anomalies are reset to zero.
Taking away the negative, all LEDs stay lighted up steady for 5 seconds (OFF) and the complete sounder test is launched.
In case of anomalies, they are duly notified.
Activated sounds: To activate sounds (three BEEPs while arming and a long BEEP while disarming) set DIP 4 in ON position.
E) RES TERMINAL, NEGATIVE INPUT OF FLASHING UNIT RESET
When set (through PONT no. 2), it stops the flashing activity of the flashing unit by taking terminal no. 6 to 0V for one second.
F) OUT ANM TERMINAL AND ANOMALY LED
The sounder is managed by a microcontroller able to check if the battery recharging process is going on properly, if the battery
status is good, if the speaker is good or faulty and if the power amps are in good condition. In case of anomaly, the open-
collector terminal OUT ANM opens and LD1 LED on the sounder board shows the fault type by making a certain number of
flashes followed by a short pause.
The microprocessor automatically performs the battery current test every 4 hours. Moreover, it continuously performs other
tests. If the sounder is correctly supplied, the anomaly output (terminal no. 7) usually stays at 0V (max consumption 50mA). If
any of the tests performed fails, the anomaly output disconnects from ground and becomes free.
When the sounder receives power supply for the first time (13V or battery), to make installation easier, anomalies are
automatically reset to zero when their cause disappears. After the first alarm trigger, anomalies are reset to zero only
through +C, RES or a command to STI.
To launch the remote test, take terminal no. 5 (STI) to 12V for 10 seconds, then take away the voltage from the terminal.
These steps launch the test which will last 60 seconds. During the test, the sounder verifies its own functioning and notifies
any anomalies both through the anomaly output (OUT ANM) and the anomaly LED, as indicated in the chart below. To reset
the anomaly to zero, remove its cause first, then wait 10 seconds and take terminal no. 5 (STI) to 12V for at least 10
seconds. When the command is taken away from terminal +C for a very short time lapse, all anomalies are reset to zero
with the exception of those concerning the battery. After 4 hours from battery restore, the sounder performs the tests
once again and updates the anomaly notices, including battery anomaly.
In case any anomaly appears, the flashing unit LEDs flash faster and the acoustic notice at arming becomes a single BEEP.
SPEAKER INTERRUPTION (test performed every 10 s)
NO RECHARGE CURRENT (recharge current is lower than 11.5V)
(test performed every 10 s)
BATTERY IS DISCONNECTED, IS LOWER THAN 2.5 V
(test performed every 4 hours)
BATTERY IS INSUFFICIENT, IS LOWER THAN 10 V
(test performed every 4 hours)
INTERNAL BATTERY RESISTOR > 3.5 OHM
(test performed every 4 hours)
SPEAKER POWER AMPs ARE INTERRUPTED
(test performed every 10 seconds)
SOUNDER IS NOT POWERED OR SOUNDER MICROPROCESSOR IS
FAULTY
NO ANOMALIES
G) ANTI-OPENING AND ANTI-REMOVAL TAMPER
CONNECTION
Connect TAMPER terminals no. 8 and no. 9 to the
tamper line coming from the control panel.
H) BATTERY CONNECTION
Connect the 12V battery to the corresponding
connector faston.
MA-SE-RTL0-03-01 Manuale Rialto Triade Lido Eng rev1
ANOMALY NOTICE CHART
ANOMALY red LED
1 FLASH
2 FLASHES
3 FLASHES
4 FLASHES
5 FLASHES
6 FLASHES
OFF
OFF
ANOMALY OUTPUT (OUT NO. 7)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT OPEN (OPEN COLLECTOR OFF)
OUTPUT TO GROUND, 0V
(OPEN COLLECTOR IS ACTIVE)