27. remove the slide bar from the shelf.
28. Unscrew the locking screw and remove the
wall bracket and wall bracket adaptor from the
slide bar.
29. Unscrew the wall bracket adaptor from the
wall bracket, then, using the wall bracket as a
guide, mark the centre of the hole position.
30. For solid walls drill the hole for the slide
bar support with a 6 mm drill and insert the
wall plug (supplied). For other types of wall
structure alternative fixings may be required
(not supplied).
Caution! To protect the surface of the shelf
protective cardboard packaging is fitted,
this must remain in place before drilling.
31. secure the wall bracket to the wall with the
screw (supplied) and screw the wall bracket
adaptor into the wall bracket.
32. slide the clamp bracket onto the slide bar.
33. attach the slide bar onto the slide bar boss and
wall bracket adaptor, making sure that they are
fitted together correctly.
34. secure the support assembly with the locking
screw, tighten using a 6 mm hexagon key
(supplied).
Caution! do not overtighten.
35. Fit the 'o' seal onto the concealing cap then
push the assembly into the end of the slide
bar.
'o' seal
36. screw the hose onto the outlet of the shower
control (make sure that the hose seal is fitted).
Do not overtighten.
37. Pass the hose behind the shelf, either on
the left or right (as desired) and screw the
remaining end onto the showerhead (make
sure that the hose seal is fitted). Do not
overtighten.
38. Place the showerhead into the clamp
bracket.
Note!
the clamp bracket is tapered so that the
showerhead will only fit from one direction. If
necessary rotate the clamp bracket through
180°.
Note! If the clamp bracket pivots downwards
under the weight of the showerhead the
central securing screw in the bracket will
require tightening to hold the showerhead in
position.