Download Print this page

Installing The Terminal Cover - Danfoss 176F6746 Installation Instructions Manual

Cable clamp kit for e3h/e4h drives vlt fc series fc 102, fc 103, fc 202, and fc 302

Advertisement

Installation Instructions

Installing the Terminal Cover

After installing the cable clamp kit, replace the terminal cover and lower cover panel using the following steps. Refer to
Illustration 1.1.
1.
Tilt the front of the terminal cover downward until
the fastener points rest on the slotted drive brackets.
2.
Make sure that the side panels of the terminal cover
are on the outside track guide.
3.
Push the terminal cover until it is positioned against
the slotted drive bracket.
4.
Tilt the front of the terminal cover upward until the
fastener hole in the drive aligns with the keyhole
opening in the terminal cover.
5.
Secure the terminal cover with 2 screws (T20). Torque
to 2.3 Nm (20 in-lb).
6.
Replace the lower cover panel and fasten with 4
screws (T25). Torque to 2.3 Nm (20 in-lb).
4
Cable Clamp Kit for E3h/E4h Drives
®
VLT
FC Series FC 102, FC 103, FC 202, and FC 302
Illustration 1.3 E3h Drive with Cable Clamp Kit Installed
Danfoss A/S © 04/2018 All rights reserved.
MI35U102

Advertisement

loading

This manual is also suitable for:

176f6747