Technibel GR120R Technical Data & Service Manual page 33

Split system air conditioner
Table of Contents

Advertisement

B. Circuit breaker trips in several minutes after turning the air conditioner on.
There is a possibility of short circuit
Check capacity of circuit
breaker.
Capacity of circuit breaker is
suitable.
Measure resistance of outdoor
fan motor winding
Measure resisatnce of
compressormotor winding
8-6-2 Neither indoor nor outdoor unit runs
A. Power is not supplied
Check power supply.
Power is being supplied to the
indoor unit
B. Check "Push bottom" selector in the indoor unit.
Push the button switch under the
indoor unit pannel.
C. Check remote control unit
Try to run with another remote
control unit.
First remote control unit is detective.
Check for residue buildup on
transmitter of remote control unit
Check for residue buildup on
remote control receiver on front
of indoor unit.
OK
NO
Replace with suitable one
(lager capacity)
In case of Heating operation:
Circuit breaker i
tripped
Power failure
The indoor unit
and outdoor unit
doesn't runs
30
Measure resistance of 4-way
valve's winding
Reset breaker
Wait for recovery
or contact power
company
Indoor PCB Ass'y
is defective
Clean transmitter..
Clean Receiver.

Advertisement

Table of Contents
loading

Table of Contents