Major Component Specifications - Technibel MCA451R Technical Data & Service Manual

Split system air conditioner
Table of Contents

Advertisement

2-2. Major Component Specifications

2-2-1. Indoor Unit
Indoor Unit
MCA451R MCA601R
Part No.
Controls
Control circuit fuse
Remote Control Unit
Type
Q´ty ... Dia. and length
Fan motor model ... Q´ty
No. of poles ...Cool / Heat rpm (High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Type
Safety
devices
Operating temp.
Run capacitor
Type
Model
Rating
Coil resistance (Ambient temp. 20°C)
Coil
Rows
Fin pitch
Face area
mm
W
Open
°C
Close
µF
VAC
mm
m2
4
WSA
Microprocessor
250 V – 3.15 A
RC– 2 ( R C )
Cross-flow
1 ... ø88 / L746
UF2– 31A5PA– S ... 1
2 ... 1305 / 1335
30
WHT – BRN : 130.4
WHT – PNK : 169.8
Thermal protector
130 ± 8
Automatic reclosing
2.0
440
Stepping motor
MP24GA2
DC 12 V
Each terminals (1–2, 1–3, 1–4, 1–5) 400 : ± 7%
Aluminium plate fin / Copper tube
2
1.3
0.250
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
– :
– :
– :