WARNINGS SAFETY WARNINGS DISPOSAL Read this manual carefully before installation and/or use of In accordance with the provisions of the following the equipment and keep it in an accessible place. European directives 2011/65/EU, 2012/19/EU and 2003/108/EC, regarding reducing the use of The Manufacturer’s Technical Dept.
MAIN VALUES SHOWN ON THE DISPLAY TIME BAND MANAGEMENT EVENTS PROFILES PARAMETERS ENABLING PRIORITY BLACK OUT EXAMPLE OF TIME BANDS PROGRAMMING EASY CLIMA CONTROLLER DESCRIPTION DESCRIPTION OF KEYS DESCRIPTION OF SYMBOLS AND ICONS DESCRIPTION OF DISPLAY SET-POINT MODIFICATION TIME BAND MANAGEMENT DIAGNOSTICS...
The display of information and programming of the device via user interface are developed in menus with navigation using the four keys as described in the relevant section. N.B. Easy Clima Controller can be coupled to hydraulic kits that manage Low Temperature and/or High Temperature systems such as: Easy Clima Kit, LT only.
Page 6
Display icons table Icon Description On with xed light On ashing Cooling icon SUMMER = ON (Cool) Heating icon WINTER = ON (Heat) Stand-by icon STAND-BY = ON Dehumidification icon DEHUMIDIFIER = ON Economy icon ECONOMY MODE = ON Alarm icon One or more alarms active Time band operating icon Time band operating enabled...
DESCRIPTION OF KEYS Description • From the main display, access is given to the user set-point menu. • From the operational parameters menu, the SET key allows you to: Short - access to the menu sub-folders press SET key - access to the value of any parameter of one of the menu sub-folders - confirm the parameter and/or output value Long press From the main display, access is given to the selection of the fundamental value to be displayed.
Display of alarm codes in progress. See relevant paragraph. ATTENTION: The set-point value will follow the trend of the room only in the presence of the Easy Clima Controller installed. If this is not the case, the set-point set can a ect the system ow temperature.
SET POINT MODIFICATION PROCEDURE HOME ......19.9 °C 16.9 °C 24.9 °C 27.9 °C 54.9 °C 20.0 °C 17.0 °C 25.0 °C 28.0 °C 55.0 °C 20.1 °C 17.1 °C 25.1 °C 28.1 °C 55.1 °C ..
EXAMPLE OF TIME BANDS PROGRAMMING Below find and example of the structure of profile 1 containing 4 events: • Event 1 = start time 06.30 – ON-Comfort operating mode • Event 2 = start time 09.30 – ON-Economy operating mode •...
Page 14
WEEKLY MANAGEMENT TABLE Below find an assignment example of the 3 profile in the days of the week: Screenshot Day Pro le te01 Monday te02 Tuesday te03 Wednesday te04 Thursday te05 Friday te06 Saturday te07 Sunday TIME BAND PROGRAMMING PROCEDURE Below find and example of the structure of profile 2 containing 4 events: •...
DESCRIPTION Room interface from Easy Clima Controller is an optional device that can be coupled to Easy Clima controller. The interface allows you to remote control the information on the Easy Clima controller in the room. Fitted with temperature and humidity probe, it allows to control the winter temperature, the summer temperature and dehumidification.
Anno Year set 10 all Display of alarm codes in progress. See relevant paragraph. TIME BAND MANAGEMENT “Time band” operation by Easy Clima controller can be activated with the “time” band management enabling parameter. HOME orol hour time For management of the time bands follow the instructions described below to access the parameters and ”3 Time Band Management”...
DIAGNOSTICS The diagnostics consists in the management of everything that is associated to the alarms. For Easy Clima device, all alarms have “automatic rearm”. Easy Clima Control unit Easy Clima Controller HOME HOME Below find the list of various alarm codes that appear and their diagnostic meaning:...