Troubleshooting - Viega MegaPress XL PressBooster 4896.2XL Instruction Manual

Table of Contents

Advertisement

MegaPress XL PressBooster - Instruction Manual
US
3.5.2 Inspection and maintenance
Have your machine serviced on schedule to ensure safety and availability. The maintenance
interval is 20,000 presses or 2 years, whichever occurs first.

3.6 Troubleshooting

Malfunction
The hinged adapter jaw is
stiff
You cannot open the hinged
adapter jaw of the
PressBooster wide enough to
attach it to the press ring
Machine will not initiate press
after starting the cycle
The PressBooster requires
more than 3 cycles to
complete a full press
The PressBooster fails to
retract fully after a third cycle
The PressBooster fails to
retract fully after a 3rd cycle
and will not release manually
Cause
The hinged adapter jaw is
dirty
The PressBooster did not
reset to the starting position
PressBooster is defective
The PressBooster is dirty or
not lubricated enough
The press tool is defective or
incompatible
The PressBooster is in need
of servicing
PressBooster is defective
13
Solution
Clean the hinged adapter
jaw, see "Cleaning" on page
12
Carry out the release cycle
press
Send your PressBooster to
your local service point
Clean and lubricate the
PressBooster, see "Cleaning"
on page 12
Check compatibility with the
Booster and use a different
press machine
Use the manual release to
loosen the jaws and send
your PressBooster to your
local service point
Contact your local Viega or
Ridgid representative