BUILT IN UNIVERSAL LIQUEFIED PETROLEUM GAS HOOK-UP: The piping up to the gas grill is the
responsibility of the installer and piping should be located as shown in the built-in instructions. A flexible
metal connector is included to simplify the installation of the unit. Connect this flexible metal connector
to the flare fitting with 3/8" SAE 45
manifold. Connect the other end of the connector to the supplied bottle regulator. Ensure that the flexible
metal connector is protected from damage if it needs to pass through any partitions. The installation must
be performed by a licensed gas fitter in accordance with AS/NZS 5601, and all connections must be leak
tested before operating the grill.
If the enclosure is to house a ULPG cylinder, the tank portion of the enclosure must be ventilated accord-
ing to the BUILT IN CYLINDER ENCLOSURE instructions, and must not have communication with the cavity
used to enclose the gas grill. A ULPG cylinder cannot be stored below the gas grill or side burner.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed ventilation opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 200 cm
for a 9.1 kg cylinder.
2. At least one ventilation opening on the exposed, exterior side of the enclosure located 25 mm or less
from the floor level. The opening must have a total free area of more than 200 cm
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
WARNING!
• The cylinder valve(s) must be readily accessible for hand operation. A door on the enclosure to gain
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the
use of tools.
• The enclosure for the ULPG-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiation, a flame barrier, and protection from foreign material, such as hot
drippings. The enclosure cannot be located directly below the grill.
• The enclosure must be designed so that the ULPG-gas cylinder can be connected, disconnected and
the connections inspected and tested outside the cylinder enclosure. Any connections that can
be disturbed when installing the cylinder in the enclosure must be accessible for testing inside the
enclosure.
OPENING
A
127 mm
MAXIMUM
OPENING
B
25.4 mm
MAXIMUM
www.napoleongrills.com
Flare Inlet Connection (5/8-18 UNF thread) on the end of the
O
864 mm
RECOMMENDED
51 mm
MINIMUM
CYLINDER SIZE
OPENING A AREA
9.1 kg
200 cm
for a 9.1 kg cylinder.
2
PARTITION TO ISOLATE
CYLINDER FROM GRILL
OPENING B AREA
2
2
200 cm
2
NON LOCKING DOOR
N415-0271-AU JAN 24.18