Download Print this page

Appendix D - Actuator F257; Mounting Parts; Actuator Mounting - Pentair F251 Installation & Maintenance Instructions Manual

Keystone hygienic butterfly valves

Advertisement

Hygienic butterfly valves model F250 & F251

Appendix D - Actuator F257

Mounting parts

Ref. No. Qty. Description
18
1
Drive boss
19
2
Bridge clamp
20
2
Screw
21
2
Spring washer

Actuator mounting

A
- When installing a double acting or spring to close actuator, put the valve in the closed
position. When installing a spring to open actuator, put the valve in the open position. The
bottom of the disc stem is marked to indicate open or closed position.
B
- Remove handle if fitted, see 6.5
C
- Fit drive boss 18 onto the valve stem square so that the actuator will be correctly orientated.
D
- Position the actuator onto the valve/drive boss.
E
- Introduce the two bridge clamps 19 and move the actuator until all the locating pins engage
in their respective holes in the actuator base and valve.
F
- While holding the bridge clamps 19 together with one hand, screw in the two screws 20 with
spring washers 21 finger tight.
G
- Torque up the two screws 20 according to torque values table:
Valve size
Torque (Nm)
25 – 65
14
80 – 100
18
125
22
H
- Cycle test actuator to ensure correct operation.
Pentair reserves the right to change the contents without notice
18
19
20
21