24 hour programmable timer

Advertisement

The volume controls can be found on the rear of the unit,
these should be adjusted with a small phillips head screw-
driver or adjustment tool.
Chime Volume controls the output level of the Chime.
Voice Over controls the level of the optional Voice Over
module (A 2072) if installed.
Alert/Evac Volume controls the level of the Alert and Evac
tones.
Adjust the output volumes to the desired levels.
T
O
HE
PTIONAL
The A 1700 timer panel has the option to fit the A 2072
voice over module. This will add a voice message to the
evacuation cycles when the evacuation cycle is triggered.
Use with the A 1700 Timer and tone generator
Connection to the A 1700 is via the 5 way keyed header
cable (JP1). The Voice-over Module will play a recorded
message twice in succession after every four evacuation
cycles. The volume control on the A 1700 Timer , labelled
"Voice over level" is used to vary the volume ratio between
the evacuation tones and the voice playback.
5 Pin Header (JP1) Pinouts
Pin
Function
1
Vcc
2
GND
3
AUDIO
4
PLAY
5
PLAYING
B
R
ATTERY
EPLACEMENT
Periodically the CR2302 lithium battery located within the
time clock (Altronics part No. S 4999) should be replaced,
this should not be necessary to be done more often than
once in 4- 5 years , or should the timer begin to loose pro-
grams or time. To replace the lithium battery in the unit,
disconnect power to the unit. Open the lid and peel off the
label on the rear of the timer. You will then see a screw type
battery cover. Un-screw this cover and remove the old bat-
tery. Checking that the orientation is correct place the new
battery in the timer and screw down the cover. The panel
should now have a reading on the display.
You will need to re-programme the settings on the timer
(refer to that part of the operating section for instructions on
re-programming the settings on the timer ).
Doc. PS1215
V
M
OICE OVER
ODULE
Description
Regulated +5V input*
Ground 0V
Audio output, line level 10kΩ
A momentary high to activate
the message playback
This line goes low to indicate a
message is currently being played
REDBACK A 1700 Programmable Timer
Pin 1
Relays
Diagram to connect up the A 2072 Voice over module to the timer.
Refer to the text and the instructions for the A 2072 to assist in the
connection
T
U
NIT DOES NOT SWITCH ON AT THE
REQUIRED HOUR
Check programs for the correct switch on times.
Check timer for the correct time.
U
NIT DOES NOT SWITCH OFF AFTER
THE ELAPSED TIME
Check timer for the correct "ON" time.
N
P
O
OWER TO
Check DC fuse.
Check power switch is on and confirm unit is plugged in
to either 24VDC or 240VAC.
T
IMER FAILS TO TRIGGER
OUT
Check that the timer 24VDC out switch is set correctly.
Check line out connections to amplifier/ preamp.
Check connections to timer 24VDC out terminals.
T
IMER FAILS TO DISPLAY OR KEEP
CORRECT TIME
Replace battery in timer.
A
/
LERT
EVAC CONTINUE TO OPERATE
AFTER THE SWITCH IS RELEASED
Check dip switch settings.
I
NCORRECT TYPE OF TONE SOUNDING
WHEN CHIME IS PUSHED
Check Dip switch settings
E
, C
VAC
HIME OR VOICE OVER LEVEL
TOO LOW
Adjust volume controls.
Mic
Use ribbon cable &
connectors provided
to join terminals (Pin
1 is the black pin)
Pin 1
ROUBLESHOOTING
U
NIT
T
IC
/ 24V
ONE
Page 3