Quick Links

NOTE: Installation wiring for the product and wiring methods shall be in accordance with the National Electrical
Code, ANSI/NFPA 70.
Product Components
1500 Series or 1600 Series Electric Strike
1
Trim Enhancer
2
1
Speci cations
ELECTRICAL RATINGS FOR
1500/1600 (Solenoid)
VOLTAGE
CONTINUOUS DUTY
INTERMITTENT DUTY*
ELECTRICAL RATINGS FOR
1500E/1600E (EcoStrike™)
VOLTAGE
IN RUSH CURRENT
CONTINUOUS DUTY
Ratings
Static Strength:
1,500 lbs
Dynamic Impact:
70 ft-lbs
Endurance:
250,000 cycles
ASSA ABLOY, the global leader
in door opening solutions
1500 Series and 1600 Series Electric Strikes
Installation Instructions
3
4
Solenoids are rated at +/- 10% indicated value.
* Applies to AC Only: 10% max duty cycle
(2 min. max on time)
12 VDC
24 VDC
12–16 VAC
-
0.24A
0.12A
-
-
0.24–0.32A
Input voltage: 10–30 VDC, Autosensing
Minimum Activation Duration: 1 second
12 VDC
24 VDC
10 VDC
0.220A
0.475A
0.460A
0.005A
0.010A
0.009A
3086006.001 Rev 3
Pigtails (12 VDC and 24 VDC)
5/64" Hex Wrench
2
4
MINIMUM WIRE GAUGE REQUIREMENTS
24 VAC
200 feet or less
-
200 - 300 feet
0.12A
300 - 400 feet
NOTE: The above table applies to Models 1500, 1500E, 1600, and 1600E.
Models 1500E and 1600E:
30 VDC
Models 1500 and 1600:
0.215A
0.004A
UL294 Performance Levels
Destructive Attack:
Line Security:
Endurance:
Standby Power:
#6-32 x 3/16" Phillips Head
5
Screws to Mount Trim Enhancer
3
5
VOLTAGE
12VDC
18 gauge
16 gauge
14 gauge
For Indoor Use Only
For Outdoor Use
Level 1 (No attack test)
Level I (No Line Security)
Level IV (100,000 cycles)
Level I (No secondary power source)
1
24VDC
20 gauge
18 gauge
16 gauge

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1500 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for HES 1500 Series

  • Page 1 1500 Series and 1600 Series Electric Strikes Installation Instructions NOTE: Installation wiring for the product and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. Product Components #6-32 x 3/16” Phillips Head 1500 Series or 1600 Series Electric Strike...
  • Page 2: Connecting The Power

    Converting the Operation Mode IMPORTANT NOTE: Converting the electric strike to FAIL SAFE mode negates the unit’s re rating. NOTE 1: The 1500 and 1600 Series Electric Strikes ship con gured for FAIL SECURE OPERATION. The steps below are provided to convert to FAIL SAFE OPERATION, if desired. The operation mode of the 1500E and 1600E (EcoStrike ) is set at the factory and cannot be changed.
  • Page 3: Preparing The Frame

    Preparing the Frame CYLINDRICAL LOCKSETS MORTISE LOCKSETS Please note the horizontal centerline of the electric strike in relation to Please note the horizontal centerline of the electric strike in relation to the centerline of the mortise lockset. the centerline of the cylindrical lockset. Inches [mm] Inches [mm] Vertical...
  • Page 4 Selecting the Appropriate Faceplate Option Frame prep (4-7/8” x 1-1/4” Square Corner) = center line (2nd Line = centerline of faceplate opening) nches [mm] 1NTD OPTION DESCRIPTION 1500 1600 For Use With: Cylindrical locksets with up to ¾” throw and all locksets with center-lined bolts. Compatible With: All brands of cylindrical latchbolts For Use With:...
  • Page 5 Adjusting the Shim NOTE: To adjust the shim height, it is necessary to power the electric strike to open keeper. STEP 1 LOOSEN the locking screw with the 5/64” Hex Wrench. STEP 2 ADJUST the shim height to the desired level by turning the upper and lower set screws (clockwise to raise and counterclockwise to lower).
  • Page 6 HES, Inc. Phoenix, AZ 800-626-7590 www.hesinnovations.com Copyright © 2018, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of 3086006.001 rev 3 Hanchett Entry Systems, Inc. is prohibited.

This manual is also suitable for:

1600 series