Page 1
USER MANUAL USER MANUAL Electronic Indicating Pressure Electronic Indicating Pressure Switch/Transmitter Switch/Transmitter S E RIE S 8 0 0/8 1 0 S ERI ES 800/810...
Exclusion of Liability NOSHOK guarantees that the pressure switch is in perfect working condition when it is delivered. The basis consists of the technical data in the data sheet and these operating instructions. Liability cannot be accepted for the suitability of the pressure switch.
Page 4
Colors of Signal Connector Round Connector Optional Wires M 12 x 1 (4-pin or 5-pin) Supply: + brown Supply: - blue Switch output S 1 black Switch output S 2 or analog output white Analog output - 2 switching option only yellow/green...
We recommend our accessories: • M12x1 socket with 2m cable - straight version, order no.: FS-2-4P/FS-2-5P (for 5-pin connection) - angled version, order no.: FA-2-4P/FA-2-5P (for 5-pin connection) - 4 and 6 meter cables also available • Protective cover Switching On and Off The pressure switch is switched on when the supply voltage is applied.
Page 6
Password protection can be activated in the main programming mode. The pressure switch is protected from unauthorized setting modi cations. If you forget the password, assistance can be obtained from NOSHOK. The serial number of the pressure switch will be needed in this case (on the label).
Page 7
Q u i c k P r o g r a m m i n g - U s e r M e n u Q u i c k P r o g r a m m i n g - U s e r M e n u Enter the quick programming user Function of the buttons: Enter the quick programming user...
Page 8
M a i n P r o g r a m m i n g - S e t U p M e n u M a i n P r o g r a m m i n g - S e t U p M e n u Enter the user menu by pressing Enter the user menu by pressing Function of the buttons:...
Page 9
M a i n P r o g r a m m i n g - C o n t i n u e d M a i n P r o g r a m m i n g - C o n t i n u e d Select the switching type of the first switching output.
Page 10
M a i n P r o g r a m m i n g - C o n t i n u e d M a i n P r o g r a m m i n g - C o n t i n u e d Select the switching type of the first switching output.
Stainless steel, ceramic with NBR seal at less than 1500 psi (standard) • Pressure connection Stainless steel Stainless steel, plastic display electronics for 800 Series; • Housing Black Anodized Aluminum for 810 Series > 10 million pressure cycles Load change Power Requirement 12...
Page 12
- Hysteresis 1 to 100% of full scale • Status indication Analog output • Signal 4 to 20 mA, 2-wire; 0 to 10 Vdc, 3-wire • Load resistance Current output: < 500 Ω, Voltage output: > 10 k Ω • Hysteresis 0.3% of full scale for ceramic cell 0.2% of full scale for thin film cell Display...
Page 13
DIMENSIONS DIMENSIONS Inches (mm) Inches (mm) 30° 30° Upper Part Rotates 330° Upper Part Rotates 330° M12x1 M12x1 1.38” (35 mm) 1.38” 3.59” (35 mm) (91.3 mm) 3.59” (91.3 mm) 1.60” (40.6 mm) 1.60” (40.6 mm) 1/4 NPT Standard 1.22” 1/4 NPT Standard 27 mm Hex (31.1 mm)
Maintenance The pressure switches that are described in this document are maintenance free. The equipment will also operate in a stable state for long periods, meaning that regular adjustment or the like is not required. Remove the device as soon as device malfunctions start to occur. The internals cannot be maintained by the customer.