Accuracy dc
80K-40:
80K-6:
Accuracy ac:
80K-40:
80K-6:
Safety:
Temperature
Operating:
Storage:
Relative Humidity:
Altitude
80K-40:
80K-6:
Dimensions (L x W)
80K-40:
80K-6:
Weight
80K-40:
80K-6:
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship
for one year from the date of purchase. This warranty does not cover
fuses, disposable batteries, or damage from accident, neglect, misuse,
alteration, contamination, or abnormal conditions of operation or handling.
Resellers are not authorized to extend any other warranty on Fluke's
behalf. To obtain service during the warranty period, contact your nearest
Fluke authorized service center to obtain return authorization information,
then send the product to that Service Center with a description of the
problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE,
ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some
states or countries do not allow the exclusion or limitation of an implied
warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
0 kV to 20 kV: 2 %
20 kV to 35 kV: ±1 % @ 20 °C to 30 °C, add
1 % @ 10 °C to <20 °C and >30 °C to 45 °C)
35 kV to 40 kV: 2 %
0 kV to 6 kV: 1 %
5 % at 60 Hz
1 % dc to 500 Hz
2 % 500 Hz to 1 kHz
-30 % typ. @ 10 kHz
IEC 61010-031, Type B, Pollution Degree 2
0 °C to 50 °C
-20 °C to +60 °C
80 % @ 30 °C
50 % @ 40 °C
2000 m, 2000 m to 5000 m: derate linearly the
working voltage from 40 kV peak to 28 kV
peak, and derate linearly the transient
overvoltage from 60 kV peak to 44 kV peak
2000 m
36 cm x 7.5 cm (14 in x 3 in)
24.9 cm x 5.10 cm (9.8 in x 2.0 in)
204 g (7.2 oz)
136 g (4.8 oz)
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
ООО «Флюк СИАЙЭС»
125167, г. Москва,
Ленинградский проспект дом 37,
корпус 9, подъезд 4, 1 этаж