Installation Guide
Installation varies slightly depending on whether you have a solenoid valve model
®
ChemiGem
or a dosing pump model. The different methods of installation are described
below, and illustrated on page 9 (Solenoid valve model) and page 10 (dosing pump
model).
Choosing a good location
®
The ChemiGem
is manufactured from weather resistant materials and is designed for
operation in full sun and rain. However, your ChemiGem
the weather. The ChemiGem
chemicals are stored (eg acid and chlorine) as vapours from these chemicals are corrosive
and may damage the electronic controls within the unit.
Insect intrusion (particularly ants) can cause problems with all equipment. Ensure that the
pool equipment area is kept free of insects as much as possible. Insect intrusion is not
covered under the warranty.
Installing the ChemiGem
Locate the ChemiGem
connected easily. Connect the ChemiGem
pool area and make sure this outlet meets all applicable Australian Standard at the time of
installation.
Mount the ChemiGem
the pool water. A mounting template has been provided with the ChemiGem
you where to place screws on either a wall or post.
The PUMP socket outlet in the base of the ChemiGem
filtration pump only. Do not use a double adaptor to connect another pump as this will
overload the system and void warranty.
®
Your ChemiGem
lighting or other pool equipment. These outlets are also timed, so accessories can be set
to come on and turn off automatically.
Installing the Injection Manifold – keep the Y-piece close to the manifold
Ensure that the suction line has no air leaks. The pump suction must be between -20kPa
and -70kPa. Turn off the pool pump before installing the injection manifold.
For solenoid valve models, the injection manifold must be installed on the inlet (suction)
side of the pump and should be positioned as close to the pump as practicable. It can be
plumbed in as an elbow or an in-line fitting. Ensure that the water flow is in the correct
direction (as marked on the injection manifold. For dosing pump models, the injection
manifold should be installed on the return (pressure) side of the pump, after any
accessories such as heaters. Make sure the Y-piece is installed close to the manifold.
®
Power Supply should not be mounted close to where
®
Power Supply
®
Power Supply close to the filtration pump so that it may be
®
Power Supply at least 1.5m above the ground and at least 3m from
has two other power outlets on its base, which can be used to run
®
will benefit if it is protected from
®
Power Supply to the mains power outlet of the
®
Power Supply is dedicated to the