Maintenance

Like all equipment the ChemiGem
operated in accordance with these instructions.
The ChemiGem
The Power Supply has been design for operation in full sun and weather. However, it will
benefit from being under cover. There is little maintenance required however – some Do's
and Don'ts –
Don't:
Install it in a small sealed enclosure (so it does not overheat)
Install it in a very hot unventilated shed (so it does not overheat)
Allow insects to nest in the unit (because they will prevent it from functioning)
Install chemical drums under or close to the unit (to prevent corrosion)
Forget about the unit once installed – it should be checked regularly to ensure
that it is working for you
Do:
Install it as per the instructions
Check it regularly
Make sure the pool balance is checked regularly
Cleaning the Multi-electrode (Probe)
®
If the ChemiGem
kit, it may be necessary to clean the multi-electrode.
To do this:
Remove the probe from the injection point by twisting the bayonet (or if fitted with
a tapping band, by unscrewing the retaining nut) and remove the o-ring.
Holding the cable, gently swirl the probe in a dilute solution of hydrochloric acid
(pool acid) for two minutes
Rinse the probe in clean water and then replace it in the injection point, making
sure that the "o-ring" is in place.
Twist bayonet to lock (or tighten nut with fingers)
®
will look better and last longer if it is maintained and
®
Power Supply
is consistently giving readings different from those obtained from a test