Installation Guide
Choosing a good location
The Ozone Chemigem is manufactured from weather resistant materials and is designed
for operation in full sun and rain. However, your Ozone Chemigem will benefit if it is
protected from the weather. The Ozone Chemigem Power Supply should not be mounted
close to where chemicals are stored (eg acid and chlorine) as vapours from these
chemicals are corrosive and may damage the electronic controls within the unit.
Insect intrusion (particularly ants) can cause problems with all equipment. Ensure that the
pool equipment area is kept free of insects as much as possible. Insect intrusion is not
covered under the warranty.
Installing the Ozone Chemigem Controller
Locate the Ozone Chemigem Controller close to the filtration pump so that it may be
connected easily. Connect the Ozone Chemigem Controller to the mains power outlet of
the pool area and make sure this outlet meets all applicable Australian Standard at the
time of installation.
Mount the Ozone Chemigem Controller at least 1.5m above the ground and at least 3m
from the pool water. A simple keyhole mount is used, see the back of the unit. When a
position is chosen, attach the 10G to 12G screw to the post or wall and hang the unit. Then
mark a point for the locator at the bottom of the unit and attach a locator screw.
The PUMP socket outlet in the base of the Ozone Chemigem Power Supply is dedicated to
the filtration pump only. Do not use a double adaptor to connect another pump as this will
overload the system and void warranty.
Your Ozone Chemigem has two other power outlets on its base, which can be used to run
lighting or an SWC unit (or other pool equipment). These outlets are also timed, so
accessories can be set to turn on and off automatically.
Installing the Injection/Probe Manifold – keep the Y-piece close to the
manifold
The injection/probe manifold should be installed on the return (pressure) side of the pump,
after any accessories such as heaters, but before the venturi injector. Make sure the Y-
piece is installed close to the manifold and that gas loops are vertical as this will
trap any gas from chemical mixing.
Installing the Probe into the Injection Manifold
The probe has a bayonet fitting. To install the probe, simply insert it into the injection
manifold and twist to lock the bayonet fitting. Ensure that the o-ring seal is not twisted or
out of place.
Chemical drums
Position the chemical drums in a safe and secure location, preferably about 2 metres from
the Ozone Chemigem. Ensure you have the right chemicals for your pool and that
chemicals have been diluted if necessary (See page 3 for safe chemical handling).
Make sure that the correct pump is connected to the correct chemical drum!