Status Indicator, Warnings and Safety Shutdowns Maintenance Troubleshooting IMPORTANT If the power cord is damaged the unit must be returned to Pool Controls for repair. Always read the instructions and warnings on chemical containers before using chemicals. Serial Number........Date of Installation........
If a defect in workmanship or materials in any Pool Controls product covered by this warranty is discovered during the term of the warranty and provided the warranty holder follows the procedure set out below, Pool Controls will repair or replace that item at the option of the warranty holder.
CALL OUT FEES • This is a “Back to Base” Warranty, which means that if the Pool Controls product needs to be serviced, replaced or repaired at a place other than Pool Controls’ premises, a call out fee will be charged to cover the cost of travel by an authorised Pool Controls technician.
The pH of the water can be lowered by the addition of acid – and your Ozone Chemigem does this automatically. The Ozone Chemigem multielectrode (probe) measures the pH of the water and doses the pool with small amounts of acid to keep the pH in the correct range.
If a Filter Cycle is active when power is returned the pump will be turned ON within 1 minute. The Ozone Chemigem will keep all its settings and will not need to be re- programmed. The Ozone Chemigem is ideal for use in systems where repeated power cuts occur, such as off-peak power circuits and Queensland’s Tarriff33 system.
Follow the directions for the initial balance for your SWC unit – the difference is likely to only be the addition of salt or minerals. Note that the Ozone Chemigem unit will turn the power to the SWC unit on and off – the SWC unit must be capable of functioning in this manner and should be set to manual operation only (not automatic).
Do not use a double adaptor to connect another pump as this will overload the system and void warranty. Your Ozone Chemigem has two other power outlets on its base, which can be used to run lighting or an SWC unit (or other pool equipment). These outlets are also timed, so accessories can be set to turn on and off automatically.
Page 10
Make sure the chemical drums are in a safe and secure location, preferably about 2 metres from the Ozone Chemigem. Connect one end of a tube to the inlet side of the valve or dose pump (the direction of flow is indicated by an arrow on a label or the front cover of each dose pump.)
If you wish to answer “yes”, press the Y/UP button. If your Ozone Chemigem also controls your pool lighting, you can turn the lights on or off manually by pressing the Y/UP button. For multi-coloured lights, hold the Y/UP button down to cycle through the various colours and release once the desired colour is reached.
7.6. Navigating the Ozone Chemigem Menu System There are three aspects to the general Ozone Chemigem Menu system – the Timer Menu, the ORP (Chlorine) Menu and the pH Menu. Access the Ozone Chemigem Menu system by pressing the ENT button and following the prompts on the LCD. If you find you have ended up in a part of the Menu system unintentionally, you can return to the Home Screen by pressing the ESC/OFF button at any time.
Timer Menu Setting the time Once you have installed your Ozone Chemigem and turned it on, you will need to set the correct time on the Chemigem 24-hour clock. First, access the Menu System by pressing the ENT button. The LCD will display the word TIMER MENU. Select this by pressing the ENT button once more.
Page 14
(see below for how to do this). Manual Light Operation If the Ozone Chemigem is turned on, the light can be turned on or off manually by pressing the Y/UP-button. If you have multi-coloured LED lights that cycle through different colours and requiring a power pulse to change effects, you can hold down the Y/UP-button to cycle through the options and release when the desired colour or effect is achieved.
ORP (Chlorine Menu) Accessing the ORP Menu Access the Chemigem Menu System by pressing ENT. Use the Y/UP or N/DOWN button to scroll through the main menu until ORP MENU is displayed on the LCD. Press ENT to select. Manual Feed Having accessed the ORP menu, the LCD will ask “Manual Feed Y/N?”.
pH Menu Accessing the pH Menu Access the Chemigem Menu System by pressing ENT. Use the Y/UP or N/DOWN button to scroll through the main menu until pH MENU is displayed on the LCD. Press ENT to select. Manual Feed Having accessed the pH menu, the LCD will ask “Manual Feed Y/N?”.
Page 17
Note: Turning off the supply of acid is not normally necessary and could lead to unbalanced pool water that is unsafe to swim in. Pool Controls recommends that you seek advice from a qualified professional prior to disabling the pH system – or call Pool Controls Service on +61 8 9240 4400.
The multi-electrode (probe) may require cleaning (see page 21 for details) If each of these factors is addressed, the Ozone Chemigem will dose the pool with chlorine until the set level is achieved – at which point the status indicator will revert to green and the warning will no longer be displayed on the LCD.
Page 19
Venturi system (if fitted) is blocked If each of these factors is addressed, the Ozone Chemigem will dose the pool with acid until the set level is achieved – at which point the status indicator will revert to green and the warning will no longer be shown on the LCD.
Troubleshooting Before requesting service, you may wish to run through the check list below but feel free to call Pool Controls Service on +61 8 9240 4400 or log a service call via our website – www.poolcontrols.com.au. If there appears to be low or no Chlorine Residual: 1.