Do's & Don'ts
DO:
• Install a bypass line around the meter
• Clean the filter on a regular basis
• Purge air from the meter before operating your system
(Flowing near the meters maximum flow rate for a
given viscosity will purge air bubbles. Tilting, tapping
or shaking the meter at lower flow rates will also
dislodge entrapped air)
Piping Diagram
Horizontal Installation
FLOW
VALVE 1
FILTER
Horizontal Two-Way Flow
VALVE 1
FILTER
Max Machinery, Inc. G-Series User Manual
FLOW METER
VALVE 2
VALVE 3
BYPASS
FLOW
FLOW METER
VALVE 2
FILTER
VALVE 3
BYPASS
© Copyright 2018
DON'T:
•
Run water or aqueous solutions through the meter
(except the 234 Series of meters)
•
Put steam or compressed air through the meter.
(Air may over-speed and damage the meter)
•
Disassemble the meter
•
Apply excessive differential pressure across the meter
•
Exceed the maximum flow rates or pressure ratings
for your meter
•
Let materials solidify in the meter
•
Try to pump through the meter if it contains frozen
material. Re-melt the material completely before
trying to pump through the flow meter.
Vertical Installation
FLOW
Rev2018A
VALVE 2
FLOW METER
VALVE 3
BYPASS
FILTER
VALVE 1
8