Meter Specifications

Model
Maximum flow rate
1
Liters/min:
Gal/min:
Maximum pressure (psi)
Maximum temperature
2
Recommended filtration
3
Displacement (cc/rev)
Weight (kg)
Typical k-factor (pulses/cc)
NPT Port size
SAE Port Size
For viscosities of 100 cps or more, derate per pressure drop curves for higher viscosities.
1
2
Standard transmitter capable to 90°C (195°F)
Some materials may have different filter requirements, consult factory.
3

Transmitter Specifications

Supply Voltage & Current
Frequency output
Analog output
Analog Resolution
Frequency Model Specifications
Output (5.0 Volt Supply)
Short Circuit Current (1)
Output Impedance
Rise/Fall Time
Output Update Rate(2)
Min/Max Frequency
Resolution
Ambient Temperature Range
Maximum Temp, Process Fluid
(20ºC Ambient, 5V supply)
Anti-dither Range Default
Signal Filtering
(1) Continuous Short Circuit is not recommended. The output current should not exceed 10 mA
(2) Events are seen as output transitions 1 ms after they occur
(3) Temperature of metered fluid will affect transmitter temperature, see graph
Max Machinery, Inc. G-Series User Manual
G004
G015
4
15
1
4
|-----------------------414 bar (6000 psi)-----------------------|
--------------------- 2 part: 225°C (435°F) --------------------
10 micron
15 micron
1.8
4.2
1.2
1.8
500
200
1/8"
3/8"
#4
#6
5-26 Vdc @ 30 mA typical
12Vdc @ 90 mA typical
24Vdc @ 45 mA typical
Adjustable without recalibration to any range of
+/- 20mA - Models ending in "A1" and "B1"
+/- 10 Vdc - Models ending in "C1" and "D1")
No Load 0.00 / 4.80 Volts
2.5K Load to Common 0.00 / 4.60 Volts
2.5K Load to +5 Volts 0.25 / 4.80 Volts
45 mA
100 Ω
0.2 μ Sec
1 ms
0-60 kHz
1 - 1000 pulses/rev
Transmitter (Storage) –40ºC to 85ºC (–40ºF to 185ºF)
Transmitter (Operation) (3) –40ºC to 80ºC (–40ºF to 175ºF)
(Standard Model)
(High Temp Model)
(Ultra High Temp Model) 225ºC (435°F)
50% Revolution of Meter for unidirectional (software selectable
from 1 - 100% of 1 revolution). 2% for bi-directional meters
Software selectable from 1ms to 250ms time constant
© Copyright 2018
G045
G105
45
105
11.9
28
20 micron
20 micron
13.5
38
3.7
7.7
70
25
1/2"
3/4"
#8
#10
90ºC (195°F)
155ºC (310°F)
Rev2018A
G240
240
64
see below
30 micron
133
21
7
1" to 280 bar (4000 psi)
#16 to 425 bar (6000psi)
5