red lion IndustrialPro BT6601 Quick Start Manual page 2

Industrialpro bt-6600 series
Hide thumbs Also See for IndustrialPro BT6601:

Advertisement

that 192.168.0.1 connects to the Ethernet cable. To connect to the USB
port use 192.168.111.1):
Troubleshooting: If BlueVue displays "Detecting Modem at 192.168.0.1" indefi-
nitely, then:
• Make sure the modem is powered on.
• Check the Ethernet Link LED on the modem. If it's off, it usually means you
have a problem with the Ethernet cable or with your computer's network
card.
• Close all other network connections (such as WiFi)
• Set your computer to obtain an IP address automatically
4.
Confirm that the modem is acquiring a cellular signal
The Signal LED should be on or flashing, indicating that the modem has a signal.
BlueVue Device Manager displays signal information in the top right of its win-
dow; a minimum of 1 bar is required to connect to the carrier with the modem.
Troubleshooting: If the Signal LED is off, then there may be an issue with the
antenna or cellular coverage might be too low in your current location.
5.
Activate the modem
1. Click on the ACT button located at the top. Click on the Carrier Provision-
ing button to open the Carrier Provisioning dialog:
2. In the Carrier Provisioning window, click on the OTASP... button and then
click OK at the warning prompt.
3. Wait for the activation process to complete.
4. Confirm the success of the number's programming
5. Click on the DIAG button located at the top left to navigate to the Modem
Diagnostic screen. Check the phone number reported by the modem
under Modem Identification: it should match the MDN provided by Veri-
zon.
CONNECT. MONITOR. CONTROL.
Troubleshooting: If the above does not occur, then the modem most likely has
no account. Contact the wireless service provider who provided you with the
account and ask them to confirm that the phone number and MIN/MSID
assigned correspond to the modem's ESN (electronic serial number), and that
the account is ready to be used.
6. Confirm the modem has successfully connected to the cellular network:
• The WAN LED will be on or flashing.
• In BlueVue, click the DIAG button, the WAN IP should indicate the IP
SETUP IS COMPLETE
The modem should be ready for use as a basic internet access point.
ADDITIONAL INFORMATION
For more advanced modem configuration, consult the support section on our
website. Visit our support page at
umentation, as well as configuration help, troubleshooting and firmware & soft-
ware updates. Or contact Technical Support at 1-877-432-9908 or
support@redlion.net.
INSTALLATION AND HAZARDOUS AREA WARNINGS
Suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations,
or non-hazardous locations only. All power, input and output (I/O) wiring must
be in accordance with Class I, Division 2 wiring methods and in accordance with
the authority having jurisdiction.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS
POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-
HAZARDOUS.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
AVERTISSEMENTS POUR INSTALLATION ET ENDROITS DANGEREUX
Cet équipement est adapté pour une utilisation en Classe I, Division 2, Groupes
A, B, C et D pour endroits dangereux , ou endroits non-dangereux seulement.
Tout câblage électrique, entrée et sortie (I / O) doivent être en conformité avec
Classe I, Division 2 méthodes de câblage et conformément à l'autorité compé-
tente.
AVERTISSEMENT - RISQUE D'AVERTISSEMENT - NE DÉBRANCHEZ PAS
L'ÉQUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU À MOINS QUE
L'ENVIRONNEMENT SOIT CONNU POUR ÊTRE NON-DANGEREUX.
AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTITUTION DE TOUT
COMPOSANT PEUT NUIRE À LA CONFORMITÉ DE CLASSE I, DIVISION 2.
© 2014 Red Lion Controls. All Rights Reserved
address assigned to the modem by the cellular network.
www.redlion.net
Quick Start Guide
to access the modem's doc-
2