Logging Into The Web Ui - D-Link DGS-3630-28TC Quick Installation Manual

Dgs-3630-28tc 20 10/100/1000base-t ports + 4 combo 10/100/1000base-t sfp ports + 4 10 gbe sfp+ ports l3 stackable managed switch
Table of Contents

Advertisement

Available languages

Available languages

Telnet client can be used to connect to the Switch using the MGMT port. To use the MGMT
port, connect one end of an Ethernet cable to a computer and the other end to the Switch.
The default IP address of the MGMT port is 192.168.0.1 and the subnet mask is
255.255.255.0. Make sure that the computer being used for the switch management has a
non-conflicting IP address in the 192.168.0.0/24 network.
To view the IP settings of the MGMT port, use the following command:
The IP settings or enabled status of the MGMT port can be changed through the console
port. For example, to change the IP address of the MGMT port, use the following
commands:

Logging into the Web UI

Supported Web browsers:
 Microsoft Internet Explorer 7 or above
 Firefox
 Google Chrome
 Safari
To access the Web UI, open a standard web browser, enter the Switch's IP address into
the address bar of the browser, and press the ENTER key. To access the Web UI from
normal LAN ports, the default IP address is 10.90.90.90. When connecting to the Web UI
of the Switch for the first time, leave the User Name and Password fields blank and click
Login since there are no login user accounts created by default on this switch.
Figure 17 — Web UI Login Window