UEi DTK2 Instruction Manual

UEi DTK2 Instruction Manual

Differential thermometer

Advertisement

Quick Links

6
SPECIFICATIONS
Temperature Units
Sensor Type
Range
-328° ~ 2498°F (-200° ~ 1370°C)
Range
-328° ~ -58°F (-200° ~ -50°C)
Accuracy
-58° ~ 1832°F (-50° ~ 1000°C)
1832° ~ 2498°F (1000° ~ 1370°C)
Accuracy (after ice-
30° ~ 120°F (-1.1 ~ 48.9°C)
point calibration)
Resolution
HOLD
Max / Min
Differential (T1-T2)
Operating / Storage
Operating Temperature
Operating RH%
< 70%RH, Non-condensing
Storage Temperature
-4 ~ 140°F (-20 ~ 60
Storage RH%
< 80%RH, Non-condensing
Battery Type
Battery Life (typical)
7
CE CERTIFICATE
The product complies with EMC directive 2004/108/EC
Technical standard: Emission EN 61326-1:2006 Class B
EN 55011:2009/A1:2010 Group 1 Class B
Immunity EN 61326-1:2006 EN 61000-4-2:2009
EN 61000-4-3:2006 A2:2010
°F / °C
k-type
Accuracy
±(0.1% rdg + 4°F (2.2°C))
±(0.1% rdg + 2°F (1°C))
±(0.1% rdg + 4°F (2.2°C))
±1°F (0.6°C)
0.1°F / 0.1°C
Yes
T1 & T2
Yes
°C)
32 ~ 104°F (0 ~ 40
°C)
1 x 9V (NEDA 1604)
125 hours typical
8
BATTERY REPLACEMENT
WARNING
If the symbol "
" appears on the LCD,
please replace the battery immediately.
• Turn off the instrument
• Remove the battery compartment
• Change the battery
• Replace the compartment cover
E N D O F L I F E
CAUTION: This symbol indicates that
equipment and its accessories shall be subject
to a separate collection and correct disposal.
9
LIMITEd WARRANTY
The DTK2 is warranted to be free from defects in materials and
workmanship for a period of three years from the date of purchase. If
within the warranty period your instrument should become inoperative
from such defects, the unit will be repaired or replaced at UEi's option.
This warranty covers normal use and does not cover damage which
occurs in shipment or failure which results from alteration, tampering,
accident, misuse, abuse, neglect or improper maintenance. Batteries
and consequential damage resulting from failed batteries are not
covered by warranty.
Any implied warranties, including but not limited to implied warranties
of merchantability and fitness for a particular purpose, are limited
to the express warranty. UEi shall not be liable for loss of use of the
instrument or other incidental or consequential damages, expenses, or
economic loss, or for any claim or claims for such damage, expenses or
economic loss. A purchase receipt or other proof of original purchase
date will be required before warranty repairs will be rendered.
Instruments out of warranty will be repaired (when repairable) for a
service charge. Return the unit postage paid and insured to:
8030 SW Nimbus Avenue, Beaverton OR 97008
• Accessories, probes and batteries (Not Covered by Warranty)
• Claims are not acceptable for improper use (including adaptation
to particular applications not foreseen in the instruction manual
or improper combination with incompatible accessories or
equipment, or for repair carried out by unauthorized personnel.)
1-800-547-5740 • FAX: (503) 643-6322
www.ueitest.com • Email: info@ueitest.com
This warranty gives you specific legal rights. You may also have other
rights which vary from state to state.
Copyright © 2013 UEi. All Rights Reserved
06/13 17018
DTK2
Differential Thermometer
INSTRUCTION MANUAL
ENGLISH
DTK2
Differential Thermometer
7
75.9
7
5 .
5.
5
. 9 . . .
9 9
9
f
f
f
f
T1
T1
T1
°
°
°
K
K
K
7
76.1
7
6.1
6.1
f
f
f
f
T2
T2
T2
°
°
°
K
K
K
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: info@ueitest.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the DTK2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UEi DTK2

  • Page 1 SPECIFICATIONS BATTERY REPLACEMENT DTK2 WARNING Temperature Units °F / °C If the symbol “ “ appears on the LCD, Sensor Type k-type please replace the battery immediately. Range -328° ~ 2498°F (-200° ~ 1370°C) • Turn off the instrument Differential Thermometer • Remove the battery compartment Range Accuracy • Change the battery • Replace the compartment cover -328° ~ -58°F (-200° ~ -50°C) ±(0.1% rdg + 4°F (2.2°C)) Accuracy -58° ~ 1832°F (-50° ~ 1000°C) ±(0.1% rdg + 2°F (1°C)) INSTRUCTION MANUAL 1832° ~ 2498°F (1000° ~ 1370°C) ±(0.1% rdg + 4°F (2.2°C)) ENGLISH Accuracy (after ice- 30° ~ 120°F (-1.1 ~ 48.9°C)
  • Page 2 KEYPAd (CONTROLS) • POWER ON/ OFF follow these steps to calibrate your meter to the thermocouple probes. Note: PRESS “UNIT” TO SELECT ˚C/˚F. Make sure you have plugged in the thermocouple probe before • ITEMS NEEDED: turning on. 1. DTK2 Thermometer Reset MAX/MIN: Press Max/Min button for 2 seconds to reset Freeze display Press and hold PWR button to turn on the meter. While the meter is 2. Two k-type probes MAX/MIN analysis value. The MAX/MIN value is updated to on, press PWR button to turn off the meter. 3. Crushed ice/water mixture current reading. (distilled water recommended if available) Press “MODE” to change operation mode T1 or T1-T2.