Jack modules with right angle wire cap

Advertisement

© Panduit Corp. 2013
7
10
1
Notes:
1. For specified performance, follow TIA/EIA 568-C installation guidelines.
2. Jack Modules can terminate 22-26 AWG solid or stranded IWC data cable with 0.062" (1.57mm) maximum insulated conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 20 times.
4. For technical and performance information, consult Panduit Technical Support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
8
EGJT
11
REMOVAL STEPS
2
www.panduit.com
Page 3 of 3
9
3
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
PN581
Important!
Maintain orientation of
cap in relation to jack
from previous steps.