Start Sequences; Standard Units - Generac Power Systems MAGNUM MLT4060MVD Owner's Manual

Light tower
Table of Contents

Advertisement

Operation

Start Sequences

This section contains diagrams of the various start sequences.

Standard Units

Dusk to Dawn Mode
ON
Controller Reads Dusk
to Dawn Sensor
No
Dark
Yes
Fuel Pump De-energizes
Display: "Cranking Rest"
"Crank Attempts" greater
30
Turn Power
Switch On
Manual or
Press Green Start
Auto Mode
Manual
Auto
Press Select Button
Scheduler Mode ON
No
Start T ime
Yes
Pin 30 on
Controller
Receives Ground
Signal
to ST AR T
Display: "Start Delay"
(5 Seconds)
Display: "Pre-Heat"
(10 Seconds)
Glow Plugs Energize
Display: "Starting"
(10 Seconds)
Display: "Cranking"
(15 Seconds)
Starter Energizes
Generator
Yes
Frequency>28 Hz
Controller verifying
engine speed
No
Starter De-energizes
(15 Seconds)
Yes
Display "Shutdown
than or equal to 3?
Failed to Start"
No
Fuel Pump Energizes
Button
Manual
Manually Select Lights
to Enable
Lights T urn On
Controller Monitors Status
Display: "Safety On"
(30 seconds)
Generator
Frequency>0 Hz
Controller verifying
engine speed
No
Display: "Loss of Crank Disconnect"
Press Select Button and Clear Alarm
END
Owner's Manual for MLT4060MVD Light Tower
Manual or
Auto Mode
Auto
Lights T urn On
Controller Monitors Status
Yes