Spark Arrester (If Equipped); Controller Features And Functions; Operator Screens; Power Zone-Dla - Generac Power Systems MAGNUM MLT4060MVD Owner's Manual

Light tower
Table of Contents

Advertisement

Spark Arrester (if equipped)

A spark arrester, installed on the engine exhaust, may be
required by code in certain municipalities. Check with the
local authority having jurisdiction to determine whether or
not a spark arrester must be installed on the unit before
operation.
G

Controller Features and Functions

(A) The Liquid Crystal Display (LCD) Window
This window displays the various operating screens. By
viewing these screens, the operator can monitor both the
engine and generator status while the unit is running.
(B) Select LED
This LED illuminates when the unit is running in AUTO
mode.
(C) Start LED
This LED illuminates when the unit is running in MANUAL
mode.
(D) Start Button
This button starts the engine if there are no shutdown
errors and the engine is in "ready to start" status.
(E) Stop Button
This button shuts down the unit and puts the controller into
STOP mode, whether in MANUAL mode or AUTO mode.
NOTE: To prevent damage to the generator and
connected equipment, remove all loads from the
generator by opening all circuit breakers (turn to the OFF
[O] position) before pressing the stop button.
(F) Stop LED
This LED illuminates when the unit is in STOP mode and
flashes when an Electrical Trip and Shutdown Fault has
occurred.
Owner's Manual for MLT4060MVD Light Tower
H
F
E
Figure 2-9. Power Zone–DLA Layout
Select
(G) Select Button
The select button navigates between AUTO and
MANUAL modes.
(H) Menu Navigation
These buttons (↑, ↓) are used to navigate through the
various operator screens.

Operator Screens

See
Figure
2-10. The operator screens display the most
relevant and critical information an operator will need to
properly configure and use the unit. From these six
screens, the operator can access information necessary
to operate the unit under normal conditions.
Figure 2-10. Operator Screens
Power Zone–DLA
See
Figure
2-9. The Power Zone–DLA (Digital Light
Tower Autolight) is an auto start controller that monitors
the unit and indicates operational status and fault
General Information
A
B
C
D
19