General Information
conditions. The controller can be programmed to
automatically start or stop based on time schedule, fault
condition, or load demand.
The controller constantly monitors vital generator and
engine functions for a number of preprogrammed alarm
and fault conditions. When a fault condition occurs, the
engine will be shut down automatically and the LCD
window will show the fault that caused the shutdown. To
resume operation, the fault condition must be corrected.
This controller also records a history of unit performance,
which may be viewed at any time and will not be lost
when the controller is powered down.
Home Screen
See
Figure
2-11. The Home screen is the default screen
of the controller and displays after the controller is
powered up and the unit management software is
loaded. It displays the controller mode, total operating
hours, hours left until the next service interval, engine
operating status, and engine RPM. If the unit is in AUTO
mode, the Home screen may also display whether the
scheduler or "dusk to dawn" are enabled.
Figure 2-11. Home Screen
Engine Screen
See
Figure
2-12. The Engine screen displays
battery voltage, oil pressure, coolant temperature
and fuel level.
Figure 2-12. Engine Screen
VBAT: Displays engine battery voltage while
running. A normal reading is 13.5-15V on 12 volt
systems.
OIL:
Displays
engine
operating pressure is between 35-80 psi (241-552
kPa).
20
002355
oil
pressure.
Normal
TEMP: Displays engine coolant temperature.
Normal operating temperature of the unit is
between 100-230°F (38-110°C).
Lights Screen
See
Figure
2-13. The Lights screen enables the operator
to turn the lights on and off. Refer to
more information.
Figure 2-13. Lights Screen
Dusk to Dawn Screen
NOTE: This feature will only work in AUTO mode.
See
Figure
2-14. The Dusk to Dawn screen enables or
disables the "dusk to dawn" function. This function uses a
photo sensor to detect the surrounding light level,
automatically starting the engine and turning the lights on
at dusk. The engine will run and the lights will remain
illuminated until dawn.
For instructions on using the Dusk to Dawn feature, see
Dusk to Dawn
Sensor.
Figure 2-14. Dusk to Dawn Screen
NOTE: This feature will only work in AUTO mode and
with a photo sensor.
Owner's Manual for MLT4060MVD Light Tower