Other Maintenance Checks - Generac Power Systems MAC 550F Owner's Manual

Flameless air heater
Table of Contents

Advertisement

Maintenance
At 1500
Operation Hours
After 1500
Operation Hours
(*) = When servicing these items, consult the equipment supplier.
NOTE: All service and maintenance or repairs are recommended to be completed by an IASD to maintain the
warranty status of a unit. You cannot be denied emissions warranty coverage solely based on failure to complete
recommended service maintenance.

Other Maintenance Checks

Every 500
Change air filter
Hours
Every 1000
Change hydraulic oil
Hours
Change hydraulic pump filters
Replace hydraulic breather/separator
Annually
Carbon Monoxide (CO) test at outlet air duct by trained service technician
Check blower/fan hardware for condition and tightness
16
Replace engine oil and oil filter element
Inspect engine accessory drive belts
Inspect fuel supply system
Clean positive crankcase ventilation valve
Check injection nozzle (*)
Replace fuel filter element
Clean water sedimenter element
Clean electromagnetic pump filter
All hours-based checks and maintenance should now be performed every 250 hours