Section 3 Operation; Before Starting Engine; Pre-Start Checklist; Engine Oil Check - Generac Power Systems MAC 550F Owner's Manual

Flameless air heater
Table of Contents

Advertisement

Section 3 Operation

Before Starting Engine

Pre-start Checklist

Remove all flammable materials and fire hazards
within 5 ft (1.5 m) of heater
Keep heater a minimum of 5 ft (1.5 m) from
structures or barricades
Verify unit is not leaking fluids: check inside and
outside the unit for leaking fuel, engine oil, HTF/
hydraulic oil, and engine coolant
Verify
following
obstructions:
– Engine air intake
– Engine exhaust stack
– Outlets and fan intakes
Verify air duct hose is securely fastened to outlet
duct assembly
Check fuel, engine oil, and engine coolant levels
Verify unit is properly secure (jack deployed,
wheels chocked) and level
Check alternator drive belt for tension and wear

Engine Oil Check

Remove dipstick from crankcase and wipe it clean.
1.
Insert dipstick fully and remove slowly.
2.
Oil level must be between the Full and Add marks
3.
on the dipstick.

Hydraulic Oil Check

On the hydraulic fluid reservoir tank is a gauge showing
hydraulic oil level. Verify the level is between MIN and
MAX.
Owner's Manual for Flameless Air Heater
are
clear
of
debris

Engine Coolant Check

Remove radiator fill cap.
1.
Check coolant level and degree of fouling. Level
2.
should be approximately 0.4 in (10 mm) below the
radiator core top.
Install radiator cap securely.
3.

Battery Check

and
Verify battery cable connections are not loose or
1.
corroded.
Verify battery electrolyte level is sufficient. If
2.
necessary, replenish with a commercially available
electrolyte, such as distilled water.
Operation
9