Toshiba RAS-M18SAH-E Service Manual page 62

Multi split wall type
Table of Contents

Advertisement

No.
Part name
Overload relay
-6
ƒ
Lower unit
The method of replacing parts of lower unit is the same as upper unit.
*
Procedure
1) Perform the process
2) Remove the terminal cover of compressor.
3) Remove OL holder and pull overload relay up.
4) Disconnect the lead wire from the overload relay
terminal.
1) Perform the process
2) Remove the base plate (Right). (3 screws)
3) Remove the drain guide. (2 screws)
4) Remove the base plate (Left). (2 screws)
-1 above.
,
above.
– 63 –
Remarks
Terminal
cover
OL holder
Parts position
Fan
motor
Compressor
(For unit C)
x 2 Screws
× 3 Screws
Compressor
(For unit D)