Microcomputer - Toshiba RAS-M18SAH-E Service Manual

Multi split wall type
Table of Contents

Advertisement

10-2. Microcomputer

RAS-13SKH-E, RAS-10SKH-E-1
No.
Part name
Common
procedure
Thermal fuse
replacement
Procedure
1) Turn the power supply off to stop the operation of air-
conditioner, and disconnect the power cord from the
AC supply.
2) Remove the front panel.
• Remove the two fixing screws. (φ4 x 14 )
3) Remove the electrical part base.
1) Perform the process
2) Remove terminal cover (Up), (Down).
3) Disconnect the terminal blocks connected with the
connecting cable, and the power cord from base E-
parts by removing the screws.
4) Remove the thermal fuse (77°C) from base E-parts.
above.
– 54 –
Remarks
Replace the thermal fuse, terminal
block, power cord, microcomputer
ass'y and the power supply P.C.
board ass'y.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10skh-e-1Ras-10skh-e-1 x 2Ras-13skh-eRas-3m31sah-e-1Ras-10skh-e-1 x 4Ras-4m36sah-e

Table of Contents