No.
Part name
„
Capacitor for
compressor
...
Capacitor for fan
motor
†
Transformer for
outdoor unit
‡
Overload relay
Procedure
1) Remove the capacitor band. (Each 1 screw)
2) Disconnect the lead wire from the capacitor terminal.
1) Remove the electrical parts cover. (1 screw)
2) Remove the capacitor band. (2 screws)
3) Disconnect the lead wire from the capacitor terminal.
1) Remove the electrical parts cover. (1 screw)
2) Remove the transformer. (2 screws)
3) Disconnect the connector from the P.C. board
assembly.
‚
1) Perform the process
2) Remove the terminal cover of compressor.
3) Remove OL holder and pull overload relay up.
4) Disconnect the lead wire from the overload relay
terminal.
above.
– 56 –
Remarks
Connector
P.C.board
support
Terminal
cover
OL holder
Parts position
Fan
motor
Compressor
(For unit A)
Compressor