History of changes....................7 Safety........................8 Safety instructions ....................8 Safety regulations for the method of operation ..........10 Standards and directives complied with.............12 Release Notes....................12 Structure and function..................13 Overview of FDSB221..................13 Overview of FDSB229..................14 Details for ordering .....................14 Product version ES.....................15 Function......................16 3.5.1 Configuration..................16 3.5.2...
Page 4
Specifications ....................31 Technical data FDSB221 ...................31 Technical data FDSB229 ...................33 Dimensions......................35 Environmental compatibility................35 Annex technical data..................36 Tones and sound levels of the interbase (DC 32 V) ..........36 Beam characteristics of the LEDs on the sounder beacon interbase (DC 32 V)39 Index ..........................41...
Technical terms 1 About this document Goal and purpose This document contains information on the sounder interbase FDSB221 and the sounder beacon interbase FDSB229. Following the instructions consistently will ensure that the product can be used safely and without any problems.
About this document Technical terms Reference document and source language The source language of this document is German (de). The reference version of this document is the international version in English. The international version is not localized. The reference document has the following designation: ID_x_en_-- x = modification index, en = English, -- = international Document identification...
About this document Applicable documents Applicable documents Document ID Title A6V10320092 Installation of sounder interbase FDSB221 and sounder beacon interbase FDSB229 008331 List of compatibility (for 'Sinteso' product line) A6V10208553 Installation of detector locking device FDBZ293 A6V10208546 Installation of detector base FDB2xx-xx, base attachment...
Safety Safety instructions 2 Safety Safety instructions The safety notices must be observed in order to protect people and property. The safety notices in this document contain the following elements: Symbol for danger Signal word Nature and origin of the danger ...
Page 9
Safety Safety instructions How risk of injury is presented Information about the risk of injury is shown as follows: WARNING Nature and origin of the danger Consequences if the danger occurs ● Measures / prohibitions for danger avoidance How possible damage to property is presented Information about possible damage to property is shown as follows: NOTICE Nature and origin of the danger...
Safety regulations for the method of operation National standards, regulations and legislation Siemens products are developed and produced in compliance with the relevant European and international safety standards. Should additional national or local safety standards or legislation concerning the planning, assembly, installation,...
Page 11
Disregard of the safety regulations Before they are delivered, Siemens products are tested to ensure they function correctly when used properly. Siemens disclaims all liability for damage or injuries caused by the incorrect application of the instructions or the disregard of danger warnings contained in the documentation.
Safety Standards and directives complied with Standards and directives complied with A list of the standards and directives complied with is available from your Siemens contact. Release Notes Limitations to the configuration or use of devices in a fire detection installation with a particular firmware version are possible.
The sounder interbase FDSB221 provides an acoustic alarm in an addressed fire detection system FS20. The sounder interbase FDSB221 can be activated by any point detector via the control panel. The loud sound of the interbase can be clearly recognized as a danger signal in the event of a fire alarm.
Synchronization of sounds with all alarm sounders, interbases and audible bases on the same detector loop No additional detector base required Optical signal transmitter Details for ordering Type Order no. Designation FDSB221 S54372-F16-A1 Sounder interbase FDSB229 S54372-F17-A1 Sounder beacon interbase Building Technologies A6V10320090_c_en_-- Fire Safety 02.11.2011...
Structure and function Product version ES Product version ES The product version ES provides the technical status of a device in terms of software and hardware. The product version is provided as a two-digit number. You will find the details of your device's product version: On the packaging label ...
Observe the 'Applicable documents' section in the 'About this document' chapter. 3.5.2 Escalation levels and sound levels Sounder interbase FDSB221 The sounder interbase FDSB221 can be activated for the following selectable escalation levels: Warning (Alert) Evacuation (EVAC) ...
The sounder interbase FDSB221 and the sounder beacon interbase FDSB229 are also activated and deactivated in degraded mode operation in the event of a fire alarm.
Structure and function Function 3.5.4 Service indicator The sounder interbase FDSB221 and the sounder beacon interbase FDSB229 have a yellow LED to indicate when servicing is required. Service indicator Behavior of LED Mode Meaning LED flashes Locate Displays the interbase location...
Living rooms and lounges Installation site The FDSB221 and FDSB229 interbases can be mounted on the ceiling or the wall. When positioning the FDSB229, bear in mind the beam angle of the LEDs. min. 2 cm Installation of the interbase on the wall or ceiling...
Planning Limitations Limitations In the case of the FDSB229 the optical signals and alarm sounds cannot be synchronized. Configuration The following chapters contain the specifications of the different acoustic and optical signals. The optical signals are only available with the sounder beacon interbase FDSB229. 4.5.1 Acoustic signals Tone...
Page 23
Planning Configuration Tone Frequency pattern Pulse pattern Adjustable max. sound Norm levels with cover plate Sweep from → to (typ. values in [dBA/1m] at 12 V at 32 V Slow-whoop 500 Hz → 1200 Hz Australia 'Action' 3.75 s Sweep-up, AS 2220 -1978 linear 0.25 s...
Planning Configuration 4.5.2 Optical signals Flash type Flashing Pulse pattern Luminous intensity at 32 V, Standard / Notes frequency angle-dependent (typ.) Flash 0.8 Hz Normal 20 ms 1.25 s Flash 0.8 Hz Normal Supervision function 20 ms 1.25 s Alternating 0.8 Hz Normal 10 ms 10 ms...
Mounting / Installation Configuration 5 Mounting / Installation The FDSB221 and FDSB229 interbases require a mounted detector base from the 'Sinteso' range. FDSB221 FDSB229 FDBZ293 FDBZ296 FDBZ293 FDBZ291 Mounting / Installation Installation sequence Detector base without point detector Installation of the interbase...
Page 26
Mounting / Installation Configuration Installation For better visibility, the designation plate should be fitted on the interbase. The detector base is fitted and installed. The detector base is in a location that allows for the beam angle in the FDSB229.
Mounting / Installation Detector locking device FDBZ293 Detector locking device FDBZ293 Using a detector locking device FDBZ293, protects a FDSB221 or FDSB229 interbase against theft. Detector locking device FDBZ293 1. Use the hexagonal wrench provided to insert the grub screw into the interbase from the detector side by turning a few revolutions.
Mounting / Installation Cover plate FDBZ296 Cover plate FDBZ296 The cover plate FDBZ296 protects the FDSB221 or FDSB229 interbase if a point detector is not being used. The cover plate is a visual element and has no electrical function. The interbase is fitted in the detector base.
Commissioning 6 Commissioning The devices are commissioned via the control panel. The exact procedure is described in the control panel documentation. Conduct a performance check once commissioning is complete. Building Technologies A6V10320090_c_en_-- Fire Safety 02.11.2011...
Maintenance / Repair Status query 7 Maintenance / Repair Status query The following actions can be performed from the control panel: Configure sounds Commissioning Activate / deactivate sound Activate/deactivate LEDs (with sounder beacon interbase FDSB229 only) Read error list / status register ...
Specifications Technical data FDSB221 8 Specifications Technical data FDSB221 Detector line Operating voltage DC 12…33 V Operating current: Standby 250 μA Sound activated 3,5 mA Quiescent current connection factor Address connection factor Separator connector factor Protocol FDnet System compatibility...
Page 32
Specifications Technical data FDSB221 Ambient conditions Operating temperature -25…+65 °C Storage temperature -30…+75 °C Air humidity ≤ 95 % rel. Protection category according to EN 60529 / IEC 60529: With point detector fitted IP21C With cover plate FDBZ296 fitted IP21C ...
Specifications Technical data FDSB229 Technical data FDSB229 Detector line Operating voltage DC 12…33 V Operating current: Standby 250 μA Sound activated 3,5 mA Light activated (luminous intensity 1.5/4.0/6.5 mA low/medium/high) Sound and light activated (luminous intensity 5.0/7.5/10.5 mA ...
Page 34
EN 54-3, type A EN 54-17 VdS approvals: G211082 LPCB approvals: FM approvals: Certificates: 0786-CPD-21099 CE conformity mark Protection categories IEC 60529 QA Standards Siemens Standard SN 36350 ISO 9001 ISO 9004 Building Technologies A6V10320090_c_en_-- Fire Safety 02.11.2011...
Specifications Dimensions Dimensions Dimensions of sounder interbase FDSB221 and sounder beacon interbase FDSB229 Environmental compatibility Reusable materials Electronic parts and synthetic materials can be easily separated Halogen-free synthetic materials, marked by embossed code The synthetic materials used do not generate any toxic substances during ...
Annex technical data Tones and sound levels of the interbase (DC 32 V) 9 Annex technical data Tones and sound levels of the interbase (DC 32 V) To indicate the effective sound level of the interbase FDSB229, a polar coordinate system is used in accordance with EN 54-3, Annex A.
Page 37
Annex technical data Tones and sound levels of the interbase (DC 32 V) Tone No. 3: Sweep-down Sound level Horizontal Vertical 15° 45° 75° 105° 135° 165° 15° 45° 75° 105° 135° 165° 0 (max.) Tone No. 4: Slow-whoop Sweep-up, linear Sound level Horizontal Vertical 15°...
Page 38
Annex technical data Tones and sound levels of the interbase (DC 32 V) Tone No. 10: Slow-whoop Sweep-up, linear Sound level Horizontal Vertical 15° 45° 75° 105° 135° 165° 15° 45° 75° 105° 135° 165° 0 (max.) Tone No. 11: Intermittent Sound level Horizontal Vertical 15°...
Annex technical data Beam characteristics of the LEDs on the sounder beacon interbase (DC 32 V) Beam characteristics of the LEDs on the sounder beacon interbase (DC 32 V) To indicate the effective luminous intensity I of the FDSB229 interbase (in accordance with the Blondel-Rey law), a polar coordinate system is used based on azimuth and elevation.
Page 40
Annex technical data Beam characteristics of the LEDs on the sounder beacon interbase (DC 32 V) Effective luminous intensity of the sounder beacon interbase FDSB229 with cover plate FDBZ296 fitted [candela] high intensity normal intensity low intensity Interbase FDSB229 with cover plate FDBZ296 Building Technologies A6V10320090_c_en_-- Fire Safety...