INSTALLATION
A) Preparatory steps which must be completed by the electrician before light
is installed, see Figure 1.
TO POWER SOURCE;
FEED PARAFFIN
RIGID CONDUIT
FOR FIBREGLASS POOL, PRE-FAB
MODULAR POOL AND VINYL LINER POOL
1) Ensure that the electrical system and its wiring for the pool conform to the requirements
of your govenment or your local authorities. The installa-tion of the Underwater Light
should only be per-formed by a licensed electrician.
a) The junction box, or the low voltage transfor-mer for 12 volt Underwater Light model is
to be located at least 120cm from the edge of the pool, see Figure 1.
b) The light fixture and all metal parts that are within 240cm of the pool must be properly
protected with non-ductile materials and that the connections must be waterproof.
c) The mounting bracket must be properly instal-led
Underwater Light lens is at least 45cm below the surface of the water in the pool, see
Figure 1.
2) Consult the local Government Building Departm-ent to be certain that the pool's
electrical system meets all applicable requirements.
B) Perform the following steps after the electrical system requirements are met.
1 Locate position on a vertical wall where light is to
)
plate must be 45 cm below normal water level, see Figure 1.
120CM MIN.
WATER LEVEL
45CM MIN. FROM WATER LINE
TO TOP OF LENS
29.6CM
6.6CM
CONCRETE MUST BE CUT BACK
AROUND NICHE TO ALLOW FOR
A COMPACT PLASTER SEAL
Figure 1.
so that the top edge of the
Be installed. The edge of the face
2-4
2 Connect conduit to midst of Mounting Spacer (left of Bracket),see Figure 2.
)
3) If pool surface is to be plastered, you must allow proper concrete cutback for
plaster thickne-ss. Finish concrete surface must be flush with Mounting Spacer.
CAUTION: Finish area surrou-nding Mounting Spacer MUST be flat and flush with the
face of Mounting Spacer, this ensures a snug fit between light and wall, see Figure 3.
4) After pool surface is finished, trim the Conduit.
5) Wrap a length of the cord up to a maximum of 2.4mt long on the back of the light
assembly. This extra cord allows you to bring the light out of the pool for relamping and
servicing.
6) Connect cord electrical wires at Junction box, through Conduit, be careful not to pull
the 75mm-80mm of slack cord at the light through the con-duit when connecting the
wires.
7) Connect all wires to the corresponding circuit wires in the junction box and feed paraffin.
8) Secure the junction box cover in place.
9) Before operating the light for more than 10 sec-onds fill pool until the Underwater Light is
comp-letely submerged in water. To check for proper operation turn on main switch
or circuit breaker as well as the switch that operates the Underwater Light itself.
10) Rotating Locking System ensures light is sec-ured to bracket, see Figure 4.(Figure 5.)
C) Winterizing: Light should be left in place for winterization.
MOUNTING BRACKET
LIGHT
CONDUIT
Figure 2.
F O R C O N C R E T E P O O L
O P E N
P O S I T I O N
F O R F I B R E G L A S S P O O L ,
P R E - F A B M O D U L A R P O O L
A N D V I N Y L L I N E R P O O L
O P E N
P O S I T I O N
DO NOT MOUNT ON:
DO MOUNT ON:
REVERSE RADIUS
IRREGULAR OR
FLAT
WALLS WITH NO TIGHTER
THAN 6 FT. RADIUS AS
SURFACE
SURFACE
UNEVEN SURFACES
VIEWED FROM TOP
Figure 3.
L O C K
P O S I T I O N
Figure 4.
L O C K
P O S I T I O N
Figure 5.
3-4

Advertisement

loading

Related Products for emaux LED-P100 Series