Rheem RJNL-A036CK Installation Instructions Manual page 32

Rjnl series; rjpl series package heat pumps
Table of Contents

Advertisement

GENERAL DATA - RJPL MODELS
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJPL - Series
Gross Cooling Capacity Btu [kW]
Cooling performance
1
EER, SEER
2
Nominal CFM/AHRI Rated CFM [L/s]
AHRI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
High Temp. Btuh [kW] Rating
Heating Performance (Heat Pumps)
System Power KW / COP
Low Temp. Btuh [kW] Rating
System Power KW / COP
HSPF (Btu/Watts-hr)
No/Type
Compressor
Outdoor Sound Rating (dB)
5
Tube Type
Outdoor Coil - Fin Type
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Tube Type
Indoor Coil - Fin Type
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
No. Used/Diameter in. [mm]
Outdoor Fan - Type
Drive Type/No. Speeds
CFM [L/s]
No. Motors/HP
Motor RPM
No. Used/Diameter in. [mm]
Indoor Fan - Type
Drive Type/No. Speeds
No. Motors
Motor HP
Motor RPM
Motor Frame Size
Furnished
Filter - Type
(NO.) Size Recommended in. [mm x mm x mm]
Refrigerant Charge Oz. [g]
Net Weight lbs. [kg]
Weights
Ship Weight lbs. [kg]
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capaci-
NOTES:
ty is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner
Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard
32
A036DL
A036DM
38,500 [11.28]
38,500 [11.28]
12/14
12/14
1200/1200 [566/566]
1200/1200 [566/566]
36,800 [10.78]
36,800 [10.78]
27,200 [7.97]
27,200 [7.97]
9,600 [2.81]
9,600 [2.81]
2.99
2.99
33,600 [9.84]
33,600 [9.84]
2.79/3.48
2.79/3.48
19,400 [5.68]
19,400 [5.68]
2.56/2.22
2.56/2.22
8
8
1/Copeland Scroll
1/Copeland Scroll
83
83
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
16.89 [1.57]
16.89 [1.57]
1 / 22 [9]
1 / 22 [9]
TX Valves
TX Valves
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
5.16 [0.48]
5.16 [0.48]
3 / 13 [5]
3 / 13 [5]
TX Valves
TX Valves
1/0.75 [19.5]
1/0.75 [19.5]
Propeller
Propeller
1/24 [609.6]
1/24 [609.6]
Direct/1
Direct/1
4000 [1888]
4000 [1888]
1 at 1/3 HP
1 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
1/10x10 [254x254]
1/10x10 [254x254]
Belt/VariableBelt/Variable
1
1
1/2
1/2
1725
1725
56
56
Disposable
Disposable
Yes
Yes
(2)1x25x16 [25x635x406]
(2)1x25x16 [25x635x406]
116 [3289]
116 [3289]
517 [235]
517 [235]
532 [241]
532 [241]
270.utdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
A036JK
A042CK
Continued ->
37,800 [11.08]
43,500 [12.75]
12/14
11.6/14
1200/1200 [566/566]
1400/1400 [661/661]
36,800 [10.78]
42,000 [12.31]
27,200 [7.97]
31,750 [9.3]
9,600 [2.81]
10,250 [3]
2.99
3.64
33,600 [9.84]
40,000 [11.72]
2.79/3.48
3.23/3.6
19,400 [5.68]
24,200 [7.09]
2.56/2.22
2.94/2.4
8
8
1/Copeland Scroll
1/Copeland Scroll
83
83
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
16.89 [1.57]
16.89 [1.57]
1 / 22 [9]
1 / 22 [9]
TX Valves
TX Valves
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
5.16 [0.48]
5.16 [0.48]
3 / 13 [5]
3 / 13 [5]
TX Valves
TX Valves
1/0.75 [19.5]
1/0.75 [19.5]
Propeller
Propeller
1/24 [609.6]
1/24 [609.6]
Direct/1
Direct/1
4000 [1888]
4000 [1888]
1 at 1/3 HP
1 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
1/10x10 [254x254]
1/10x10 [254x254]
Belt/Variable
Direct/3
1
1
1/2
1/2
1075
1075
48
48
Disposable
Disposable
Yes
Yes
(2)1x25x16 [25x635x406]
(2)1x25x16 [25x635x406]
116 [3289]
120 [3402]
517 [235]
521 [236]
532 [241]
536 [243]
8