4.3.1 Configuration Implementation

4.3.1.1 Configuration Description
According to the service requirements in Fig. 4.3-2, the required boards are analyzed as
follows:
1.
2.
2+1 wave
Add/drop
15km
5km
B
osc
osc
Integrated access without OTU
Configure OTU
Configure OTUP (with protected OUT; dotted line indicating the protection route)
Optical monitor
One board

Fig. 4.3-2 Service Requirements

NCP board
One NCP board should be configured for each node and be installed in the
master CWU shelf.
As the ZXMP M600 is configured as OADM equipment in the global network
and the monitoring channel is 1310nm, NCP board of which the monitoring
channel type is line and the wavelength is 1310nm should be configured in each
node.
PCW board
Two same PCW boards will be configured for each shelf according to the type
of DC power supply equipped in the machine room.
2+1 wave
2+1 wave
Add/drop
Add/drop
18km
C
D
osc
4-8
2+1 wave
2km
Add/drop
20km
E
osc
osc
2xGE
4x622M