6.
7.

2.8 Indices of System Component Parts

2.8.1 Performance Indices of OMD

OMDs used in the ZXMP M600 equipments include OMD5-1, OMD4-1 and OMD4-5.
The figures before "-" respectively indicate the number of the channels on the board,
while the figures after "-" respectively indicate the serial number of the starting
wavelength.
The optical interfaces of each board are shown in Fig. 2.8-1.
UPG: Upgrade interface; Ln: line interface; CH0: 1310 window; /I: input; /O: output
Different OMD units can be combined to implement the multiplexing/demultiplexing
of different wavelengths.
1.
All the laser modules in the equipment comply with the requirements of IEC
60825-1:1994+A2:2001 and IEC 60825-2:2000.
Reproduction of all warning labels.

Fig. 2.8-1 Optical Interfaces of OMD Units

OMD5-1: multiplexing/ demultiplexing 4+1 wavelengths. "+1" indicates the
1310 channel.
2-7