Page 1
FSAP 9800 Full Service Access Platform Hardware Manual Version 3.0.0 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 Fax: (86) 755 26770801 URL: http://ensupport.zte.com.cn E-mail: support@zte.com.cn...
Page 2
The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO- RATION is prohibited.
FSAP 9800 (V3.0.0) Full Service Access Platform. Intended This document is intended for engineers and technicians who per- Audience form operation activities on FSAP 9800 (V3.0.0) Full Service Access Platform. Prerequisite Skill To use this manual effectively, users should have a general under- and Knowledge standing of telecommunications technology.
Page 6
You can also call our customer support center at (86) 755 26771900 and (86) 800-9830-9830. ZTE welcomes your comments and suggestions on the quality and usefulness of this document. For further questions, comments, or suggestions on the documentation, you can contact us by e-mail at doc@zte.com.cn;...
A single shelf provides 1792 lines. � Configured without the splitter shelf, one 19D06H22 cabinet can hold three subscriber shelves. A single shelf provides 2688 lines. Figure 3 shows the components in FSAP 9800 19D06H22 cabinet. Confidential and Proprietary Information of ZTE CORPORATION...
Page 10
FSAP 9800 Hardware Manual 3 COMPONENTS IN FSAP 9800 19D06H22 CABINET IGURE 19D06H16 19D06H16 cabinet can be configured with a splitter shelf or without a splitter shelf. � Configured with the splitter shelf, one 19D06H16 cabinet can hold one subscriber shelf. A single shelf provides 896 lines.
FSAP 9800 Hardware Manual 5 CABINET ASSEMBLY DIAGRAM IGURE Cabinet Components Besides cards, service shelf and splitter shelf, FSAP 9800 cabinet has the following components. � Power distributor � Fan tray � 3U cable rack (only for FSAP 9800) �...
Monitors environment parameter and power supplies. It monitors the primary power, AC, secondary power, distribution frame alarm. It also monitors environment factors like smog, flood, theft, and temperature. Power Distributor Introduction FSAP 9800 supports two power distributors: � PWRS � PWRC PWRS...
FAN on the panel is a monitoring port. 3U Cable Rack Introduction The 3U cable rack is used for wiring. Outline dimensions 130.55 mm×482.6 ×188 (Height×Width×Depth). Figure 7 shows the outline of a 3U cable rack. Confidential and Proprietary Information of ZTE CORPORATION...
9 FRONT PANEL IGURE Back Panel Figure 10 shows the back panel of a line tester. 10 BACK PANEL IGURE Table 3 lists the interfaces functions on the back panel. Confidential and Proprietary Information of ZTE CORPORATION...
Tester is working. Tester is in standby status. ERROR Tester is faulty. EPM Unit Introduction An EPM unit monitors the environment parameters. Outline dimensions 43.6 mm×482.6 mm×271 (Height×Width×Depth). Figure 11 shows an EPM unit. Confidential and Proprietary Information of ZTE CORPORATION...
Page 17
Fan Hand � Reserve Out1 � Reserve Out2 � Reserve In1 � Reserve In2 � Gard2 � Hum2 � Smoke2 � Liquid2 � Temp2 � 232-3 � Test � 485-1 � 485-2 � Confidential and Proprietary Information of ZTE CORPORATION...
� Keep average luminance within 150 Lx ~ 200 Lx, without flare. � Light the equipment room by fluorescence lamps embedded in the ceiling. � Equip the room with emergency lights. Confidential and Proprietary Information of ZTE CORPORATION...
Page 19
9800 splitter backplane 436.6 mm × 395.2 mm (W × H) Note: H – Height ; W – Width ; D – Depth Weight 19D06H22 cabinet is 110 kg. 19D06H16 cabinet is 91 kg. Confidential and Proprietary Information of ZTE CORPORATION...
Page 20
GPON ports in a single shelf Using MDCA/MDCE backplane: 8 Using MDCF backplane: 14 Shelf Power FSAP 9800 single shelf power consumption (with full configura- Consumption tion): 1500 W Card Power Table 8 lists FSAP 9800 card power consumption.
Page 21
INVNA PNVNP Operation Voltage Table 9 lists FSAP 9800 operation voltage. 9 OPERATION VOLTAGE ABLE Type Voltage DC operation voltage Rated voltage: -48 V DC Range: -57 V DC ~ -40 V DC Confidential and Proprietary Information of ZTE CORPORATION...
Page 22
FSAP 9800 Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
Introduction FSAP 9800splitter shelf holds the DSL splitter cards, line-capture control card, environment and power monitoring card. Dimensions FSAP 9800 splitter shelf dimensions are 399.2 mm×482.6 mm×387.5 mm (Height ×Width×Depth). Figure 14 shows FSAP 9800 splitter shelf structure. Confidential and Proprietary Information of ZTE CORPORATION...
� MDCF FSAP 9800 (V3.0.0) splitter shelf supports one backplane: MTAN. MDCA Introduction MDCA is one of FSAP 9800 backplanes. MDCA backplane works with the control and switch card CSCA/CSCE/CSCM/CSCT. Functions The functions are as follows: � Supports broad/narrowband integrated service access �...
X138) FAN POWER (X139) Socket Reserved MDCE Introduction MDCE is one of FSAP 9800 backplanes. MDCE backplane works with the control and switch card CSCA/CSCE/CSCM/CSCT. Functions The functions are as follows: � Supports pure broadband service access Confidential and Proprietary Information of ZTE CORPORATION...
Page 27
Type Description Interface RJ-45 TEST 1/UPLINK 1 Reserved (X21) DNLINK (X22) RJ-45 Reserved RJ-45 CSV (X23) Reserved FAN POWER (X139) Socket Reserved -48 V POWER (X140, Socket Connects to -48 V DC X138) Confidential and Proprietary Information of ZTE CORPORATION...
FSAP 9800 Hardware Manual MDCF Introduction MDCF is one of FSAP 9800 backplanes. MDCF backplane works with the control and switch card MSCT/MSCX. Functions The functions are as follows: � Supports larger bandwidth, each slot’s bandwidth reaching up to 4 GE. Provides two 10G interface uplink slots.
Reserved FAN POWER (X139) Reserved -48 V POWER (X140, Connects to -48 V DC X138) MTAN Introduction MTAN is FSAP 9800 splitter shelf backplane. Functions The functions are as follows: � Mechanical support for cards � Power supply � Management communication channels from the control and...
FSAP 9800 Hardware Manual 18 MTAN BACKPLANE IGURE Shelf Configuration FSAP 9800 can hold a subscriber shelf and splitter shelf. The split- ter shelf is optional in configuration. This topic describes shelf configurations, including: � Subscriber shelf configuration � Splitter shelf configuration...
19 FSAP 9800 SPLITTER SHELF SLOT DISTRIBUTION IGURE � The slots corresponding to the power card slots of FSAP 9800 subscriber shelf are for the line test card (LTN). � Slots 2 ~ 8, Slot 10 and Slots 12 ~ 17 are for the splitter cards.
� NE cascading � Test cascading NE Cascading Introduction FSAP 9800 provides different electrical and optical Ethernet ports for uplink/ cascade. These ports are: � 10 Mbps/100 Mbps/1000 Mbps Ethernet electrical ports for up- link/cascade � 100 Mbps/100 Mbps optical ports for uplink/cascade �...
PDBX card provides two RJ-45 ports for NE test cascading. These ports transmit data when several cascading NEs use one tester. In this mode, when several NEs are cascaded, their respective PDBX cards are also cascaded and line test functions are performed. Confidential and Proprietary Information of ZTE CORPORATION...
Page 34
FSAP 9800 Hardware Manual This page is intentionally blank. Confidential and Proprietary Information of ZTE CORPORATION...
C h a p t e r Cards Table of Contents List of Cards ..............29 Card Description..............30 List of Cards FSAP 9800 system uses the following cards: � Control and switch card CSCA � CSCE � CSCM � CSCT �...
� � � Card Description This topic describes all cards used in FSAP 9800. CSCA Card Overview CSCA card is the core of control and switching in the system. It provides powerful switching capability and a series of ports on the backplane.
Page 37
100Base-TX Ethernet port; used for out-of-band NM and debugging Debugging console port Connected to the fan tray or EPM unit for monitoring Test interface port Panel Description Figure 21 shows CSCA card front panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 38
LED indicators on a CSCA panel. 14 CSCA PANEL INDICATORS ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. MAIN Green Card is active. Card is standby. Confidential and Proprietary Information of ZTE CORPORATION...
100Base-TX Ethernet port; used for out-of-band NM and debugging Debugging console port Connected to the fan tray or EPM unit for monitoring Test interface port Panel Description Figure 22 shows CSCE card front panels. Confidential and Proprietary Information of ZTE CORPORATION...
Page 40
FSAP 9800 Hardware Manual 22 CSCE PANELS IGURE Table 16 lists LED indicators on a CSCE panel. Confidential and Proprietary Information of ZTE CORPORATION...
It supports Layer-3 version functions. Interfaces CSCM supports upper and lower sub-cards, which provide inter- faces for uplink/cascade. Table 17 lists interfaces on the panel of a CSCM card. Confidential and Proprietary Information of ZTE CORPORATION...
Page 42
100Base-TX Ethernet port; used for out-of-band NM and debugging Debugging console port Connected to the fan tray or EPM unit for monitoring Test interface port Panel Description Figure 23shows CSCM card front panels. Confidential and Proprietary Information of ZTE CORPORATION...
Page 43
Chapter 3 Cards 23 CSCM PANELS IGURE Table 18 lists LED indicators on a CSCM panel. Confidential and Proprietary Information of ZTE CORPORATION...
It supports Layer-2 version functions. It supports 16K MAC addresses Interfaces CSCT supports upper and lower sub-cards, which provide inter- faces for uplink/cascade. Table 19 lists interfaces on the panel of a CSCT card. Confidential and Proprietary Information of ZTE CORPORATION...
Page 45
Connected to the fan tray or EPM unit for monitoring Test interface port Panel Description Figure 24 shows CSCT card front panels. 24 CSCT PANELS IGURE Table 20 lists LED indicators on a CSCT panel. Confidential and Proprietary Information of ZTE CORPORATION...
It supports Layer-3 version function and narrowband service access. Interfaces MSCT supports upper and lower sub-cards, which provide inter- faces for uplink/cascade. Table 21lists interfaces on an MSCT panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 47
Connected to the fan tray or EPM unit for monitoring 10 M/100 M Ethernet electrical interface, used for test 2MI- 2 Mbps/2 MHz BITS clock interface (coaxial interface) Panel Description Figure 25 shows MSCT panels. Confidential and Proprietary Information of ZTE CORPORATION...
Page 48
LED indicators on an MSCT panel. 22 MSCT PANEL INDICATORS ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. MAIN Green Card is active. Card is standby. Confidential and Proprietary Information of ZTE CORPORATION...
Electrical or optical interfaces 10GE optical interface 10 M/100 M Ethernet electrical interface, used for out-of-band RS-232 serial port, used for debugging or hyper terminal operation Connected to the fan tray or EPM unit for monitoring Confidential and Proprietary Information of ZTE CORPORATION...
Page 50
10 M/100 M Ethernet electrical interface, used for test 2MIN 2 Mbps/2 MHz BITS clock interface (coaxial interface) Panel Description Figure 26shows MSCX panels. 26 MSCX PANELS IGURE Table 24 lists LED indicators on an MSCX panel. Confidential and Proprietary Information of ZTE CORPORATION...
There is a RST button on each MSCX panel for resetting the card. Ethernet Interface Sub-cards Ethernet interface sub-cards are sub-cards used together with the control and switch cards. Table Table 26 Table 27 list the combination of control and switch card’s Ethernet interface sub-cards. Confidential and Proprietary Information of ZTE CORPORATION...
Page 52
OGFB SGFB 1000 M Ethernet 1000 M Ethernet 2-channel 4-channel optical optical interface sub-card interface sub-card TGFC 10/100/1000 SGFB 1000 M Ethernet 2-channel M Ethernet optical interface sub-card 4-channel Confidential and Proprietary Information of ZTE CORPORATION...
Page 53
+ 10/100/1000 M Ethernet module 2-channel electrical interface sub-card SGFE 1000 M Ethernet 2-channel optical 10 G optical interface + 10/100/1000 M Ethernet module 2-channel electrical interface sub-card No sub-card 10 G optical module Confidential and Proprietary Information of ZTE CORPORATION...
10 G optical module is not a sub-card. It resides at the sub-card place. AINC Card Overview AINC is ATM interface card used in FSAP 9800 (V3.0.0). AINC provides ATM interfaces for cascade or uplink. It supports ATM/E1/IMA access. There are two sub-card sockets on AINC card. The upper one is for AICA sub-card.
Page 55
27 AINC PANELS IGURE Table 29 lists LED indicators on an AINC panel. 29 AINC PANEL INDICATORS ABLE Name Color Status Meaning Green Card is powered Flashing Card is working normally. Flashing Card is faulty. Confidential and Proprietary Information of ZTE CORPORATION...
� When IMCA is configured, indicators 5 to 20 are used. EINT Card Overview EINT card is FSAP 9800 10G optical interface card. It provides 1 10 GE Ethernet interface for uplink. Interfaces Table 30 lists interfaces on the panel of an EINT card.
Page 57
LED indicators on the EINT panel. 31 EINT PANEL INDICATORS ABLE Name Color Status Meaning Green Flashing Card is working normally. CPLD is not burnt or card is power OFF. Green 10 GE PHY link is established. Confidential and Proprietary Information of ZTE CORPORATION...
The interface is receiving/trans- mitting data. EINB Card Overview EINB card is FSAP 9800 2GE/4GE optical interface card. It provides 2 or 4 GE Ethernet interfaces for uplink. Interfaces Table 32 lists interfaces on the panel of an EINB card.
Page 59
LED indicators on the EINB panel. 33 EINB PANEL INDICATORS ABLE Name Status Color Meaning Green Flashing Card is working normally. CPLD is not burnt or card is power OFF. G1 – G4 Green There are signals. Confidential and Proprietary Information of ZTE CORPORATION...
PSTN exchange Panel Description On an ATNG panel, there are: � One LED indicator � 32 link LED indicators � Two sockets � A reset button Figure 30 shows an ATNG card panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 61
LED indicators on an ATNG panel. 35 ATNG PANEL INDICATORS ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. Link indicators Green Link is established. Link is broken. Confidential and Proprietary Information of ZTE CORPORATION...
36 ASNV PANEL INTERFACES ABLE Description Connected to the ADSL2 interface on the splitter card Connected to the ADSL1 interface on the splitter card Panel Description Figure 31 shows the front panel of an ASNV card. Confidential and Proprietary Information of ZTE CORPORATION...
Flashing Card is working normally. Flashing Card is faulty. ISNV Card Overview ISNV card is an ADSL2+ over ISDN subscriber card. It works to- gether with remote ATU-R to provide 64-channel ADSL2+ over Confidential and Proprietary Information of ZTE CORPORATION...
Page 64
38 ISNV PANEL INTERFACES ABLE Description Connects to the ADSL2 interface on the splitter card Connects to the ADSL1 interface on the splitter card Panel Description Figure 32 shows front panel of an ISNV card. Confidential and Proprietary Information of ZTE CORPORATION...
Page 65
32 ISNV CARD PANEL IGURE Table 39 lists the LED indicator on an ISNV panel. 39 ISNV PANEL INDICATOR ABLE Name Status Color Meaning Green Flashing Card is working normally. Flashing Card is faulty. Confidential and Proprietary Information of ZTE CORPORATION...
VDSL2), which provide 48 ports for VDSL2 subscriber access. Panel Description Figure 33shows the front panel of a VSNKC card. 33 VSNKC PANEL IGURE Table 40 lists the LED indicator on a VSNKC panel. Confidential and Proprietary Information of ZTE CORPORATION...
Interfaces STNG has a USER interface on its front panel, which provides 32 ports for SHDSL subscribers. Panel Description Figure 34 shows the front panel of a STNG card. 34 STNG PANEL IGURE Confidential and Proprietary Information of ZTE CORPORATION...
STU-R to provide 32-channel SHDSL subscriber access. Interfaces SSNG has a USER interface on its front panel, which provides 32 ports for SHDSL subscribers. Panel Description Figure 35 shows the front panel of a SSNG card. Confidential and Proprietary Information of ZTE CORPORATION...
Page 69
35 SSNG PANEL IGURE Table 42 lists the LED indicator on a SSNG panel. 42 SSNG PANEL INDICATOR ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. Confidential and Proprietary Information of ZTE CORPORATION...
FSAP 9800 Hardware Manual Splitter Cards Overview Splitter card separates voice signals from service signals. It works together with service cards and transmits service signals to them. Types FSAP 9800 has five types of splitter cards: � PNVNA � PNVTA �...
Page 71
Chapter 3 Cards 36 PNVNA CARD PANEL IGURE Figure 37 shows a PNVTA card panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 72
FSAP 9800 Hardware Manual 37 PNVTA CARD PANEL IGURE Figure 38shows a PNVNP card panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 73
Chapter 3 Cards 38 PNVNP CARD PANEL IGURE Figure 39 shows an INVNA card panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 74
FSAP 9800 Hardware Manual 39 INVNA CARD PANEL IGURE Figure 40 shows a VNKN card panel. Confidential and Proprietary Information of ZTE CORPORATION...
EPON system functions at OLT side. Interfaces EPN provides one EPON interface on its panel. Panel Description EPN panel has a RST button for resetting card. Figure 41 shows an EPN card panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 76
LED indicators on an EPN panel. 45 EPNC PANEL INDICATORS ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. Green Flashing Link is estab- lished. The port is receiv- ing/transmit- ting data. Confidential and Proprietary Information of ZTE CORPORATION...
GPNC card. 46 GPNC PANEL INTERFACES ABLE Name Description GPON interface GPON interface Panel Description GPNC panel has a RST button for resetting card. Figure 42 shows a GPNC panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 78
IGURE Table 47 lists LED indicators on a GPNC panel. 47 GPNC PANEL INDICATORS ABLE Name Color Status Meaning Card is faulty. Green Flashing Card is running normally. Yellow ON/Flashing Software version problem. Confidential and Proprietary Information of ZTE CORPORATION...
These lines are provided to a tester. Interfaces LTN can be powered via its front panel or backplane. FSAP 9800 shelf provides –48 V power to the LTN card via 3-core socket on its front panel.
Page 80
43 LTN CARD PANEL IGURE Table 49 lists the LED indicator on a LTN panel. 49 LTN PANEL INDICATOR ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. Confidential and Proprietary Information of ZTE CORPORATION...
Combined internal test bus, external test bus and test bus functions Panel Description Figure 44 shows a PDBX card panel. 44 PDBX CARD PANEL IGURE Table 51 lists the LED indicator on a PDBX panel. Confidential and Proprietary Information of ZTE CORPORATION...
2 Fan tray RJ-45 Fan3 Connects to fan monitoring tray. interface 3 PowerP RJ-45 Power P Digital traffic monitoring input interface (Power P monitoring) D_out RJ-45 None Digital traffic output interface Confidential and Proprietary Information of ZTE CORPORATION...
Page 83
-48 V power 3-core PCB Cards power supply interface socket supply Note: ss1 and ss2 are ON/OFF switch on EPS card, controlling RS-232/RS-458 serial port. Panel Description Figure 45 shows an EPS card panel. Confidential and Proprietary Information of ZTE CORPORATION...
Page 84
45 EPS CARD PANE IGURE Table 53 lists the LED indicator on an EPS panel. 53 EPS PANEL INDICATOR ABLE Name Color Status Meaning Green Flashing Card is working normally. Flashing Card is faulty. Confidential and Proprietary Information of ZTE CORPORATION...
- Optical Network Unit POTS - Plain Old Telephone Service PSTN - Public Switched Telephone Network SHDSL - Single-pair High Digital Subscriber Line VDSL2 - Very High Bit Rate Digital Subscriber Line 2 Confidential and Proprietary Information of ZTE CORPORATION...