Bartington Mag-01 Operation Manual

Single axis fluxgate magnetometers with mag probes b-g
Hide thumbs Also See for Mag-01:

Advertisement

Quick Links

Specifications may be subject to slight alteration without prior notice.
This system is not qualified for use in explosive atmospheres or life
support systems. Consult Bartington Instruments for advice.
The copyright of this document is the property of Bartington
Instruments Ltd. The document is supplied on the condition that it
(89/336/EEC)
is to be treated commercially confidential and it may not therefore
EMC DIRECTIVE
be disclosed to any third party without written authorisation of the
Managing Directors of Bartington instruments
Bartington Instruments Limited
5 & 10 Thorney Leys Business Park
Witney, Oxford, OX28 4GE, England.
OM0382
Operation Manual for
Mag-01 & Mag-01H Single Axis Fluxgate
Magnetometers with MAG Probes B-G
T:
+44 (0)1993 706565
F:
+44 (0)1993 774813
E:
sales@bartington.com
www.bartington.com

Advertisement

Table of Contents
loading

Summary of Contents for Bartington Mag-01

  • Page 1 This system is not qualified for use in explosive atmospheres or life support systems. Consult Bartington Instruments for advice. The copyright of this document is the property of Bartington Instruments Ltd. The document is supplied on the condition that it...
  • Page 2: Table Of Contents

    Mag-01 and Mag-01H electronics units Mag probes Accessories LIST OF FIGURES Note: All dimensions are in mm Figure 1 Analog output frequency response for Mag-01 and Mag-01H Figure 2 Mag-01 front panel functions Figure 3 Mag-01H front panel functions Figure 4...
  • Page 3: Introduction

    A precision voltage to current converter maintains precise calibration over the full range of operating temperatures. The Mag-01H differs from the Mag-01 due to the addition of a x10 sensitivity control to increase resolution and the provision of a precision offset control to expand the measuring range.
  • Page 4: Power Supplies And Battery Charging

    Power supplies and battery charging The instruments are powered either continuously from the mains, via a power supply, or from the internal 6V rechargeable battery. The battery provides more than 12 hours continuous use. It can be recharged at 12V either from the mains or from a vehicle battery.
  • Page 5: The Probes

    ±1__________. The sign is preserved but only the leading 1 will be displayed. Analog output - See figure 1 The Mag-01 is primarily intended for the long term precise investigation of static or slowly varying, low intensity magnetic fields. The frequency response of the instrument is tailored to remove noise from high frequency sources.
  • Page 6: Vector Sensing

    Vector sensing The cores within the probe only respond to the component of a magnetic field which is along the axis of the cores. The probes are therefore vector sensing and produce a cosine directional response. The measured value V = Bmax Cosθ where Bmax is the total field strength and θ...
  • Page 7 Special probe type D/S possesses a shorter (9mm) sensing element and, when used in conjunction with the Mag-01(H) specially set up for the purpose, will permit measurements using the analog output of up to ±5.3V, equivalent to ±5.3mT, with the probe at a temperature no higher than 25 C.
  • Page 8: Conventions

    Mounting the Cryogenic Probe The probe can be mounted by bonding, using a minimal mount epoxy adhesive, or by loosely supporting the probe within a tube. Proximity Effects No two Mag cryogenic probes should be operated within 10mm of each other if interaction is to be avoided.
  • Page 9: Battery Replacement

    Instructions for battery replacement Remove the two case retaining screws in the base of the instrument and remove the top cover. Disconnect the battery leads (Mag-01) or the battery connector (Mag-01H) and fit a replacement battery. Re-connect. 4.2 Electromagnetic compatibility The Mag-01 and Mag-01H instruments contain no high frequency electronics likely to cause emissions which could affect other apparatus.
  • Page 10: Technical Specifications

    TECHNICAL SPECIFICATIONS Mag-01 and Mag-01H electronics units Measuring range 0 to 0.2mT or 2mT depending on probe Bandwidth (low field probes) 0 to 10Hz, 20μT pk-pk, -12dB per octave roll off Calibration accuracy 0.1% (for ultimate accuracy see probe specifications) Maximum resolution 1nT (Mag-01), 0.1nT (Mag-01H)
  • Page 11: Cryogenic Probes

    10m Materials axial and transverse probes glass fibre reinforced plastic with brass jacket Dimensions see Mag-01 & Mag-01H brochure DS0003 ACCESSORIES Supplied Universal AC mains adaptor for 110V or 220/240V with outlet adaptors Vehicle dashboard connector - 12 V DC...
  • Page 12: Analog Output

    0.1μT B Peak (µT) measured ROLL OFF: -40dB/DECADE at V a out -12Bd/OCTA VE 0.01 Figure 1 ANALOG OUTPUT FREQUENCY RESPONSE FOR Mag-01 & Mag-01H DR0233(4) Mag -01 POWER POWER SWITCH 4 1/2 DIGIT LCD DISPLAY ILLUMINATED Displays directly in...
  • Page 13 12V DC z=1k W POLARITY PROTECTED FULL CHARGE 6 HOURS 2.1mm d.c. inlet Charge from mains adaptor or vehicle dashboard cable Voltage may be between 9-18V Figure 4 Mag-01 / Mag-01H REAR PANEL FUNCTIONS OM0382 ISSUE 8 PAGE 13 OF 14...
  • Page 14 BATTERY CHARGER INPUT REGULATED FILTER POWER SUPPLY CHARGE INDICATOR POWER 6V 1.1Ah ON / OFF SEALED BATTERY Figure 5 Mag-01 SYSTEM SCHEMATIC DR0223(4) A-D CONVERTOR & 4 1/2 DIGIT LCD RANGE CONTROL +19.999 SWITCH SUMMING AMPLIFIER & ATTENUATOR PRECISION VOLTAGE TO...

This manual is also suitable for:

Mag-01h