XL CONFIRMATION OF DISTANCE CONSTANT
r
f
The SDM3E is quality-controlled to have a nil distance constant.
The distance constant rarely changes. However, when some con-
stant error seems to exist in measurements or as a periodical
check (several times a year), check the distance constant as follows.
1
I, Confirmation of the distance constant K.
Select points A and B on a flat ground about 330 ft (100 m)
in between, and C in the middle.
2. Set up the SDM3E at A, and measure the distance AB.
j....'" '. ..., ..., '3,o.ftJ'CJ"".,..,..,....umu'i
A B
F ig. 128
.
i
I:
Ie.
l
I'
I~
3.
Shift the SDM3E to C, and measure the distances CA and CB.
t:
it
W
If
it.
~ ,.
, :
jUuuu'lmumuuumml
A
c
Fig. 129
B
4.
Compute the distance error K with the formula:
K = AB- (CA + CB)
5.
Obtain K more than two or three times. If the K is far from
nil, contact our agent.
í
,
I
i
I
i.
'\
\.
87