Download Print this page

Newport i/8 Quick Start

I series temperature/process controller with isolated analog output board

Advertisement

Quick Links

FLOW CHART
d
d
d
d
a
a
a
d
a
a
INPUT MENU SETUP
(operation example)
Below is a flowchart showing how to navigate through the
submenus of Input menu item by pressing the front buttons.
b
d
b
d
• • •
b
b
d
d
a
• • •
d
b
b
d
a
• • •
d
b
b
d
• • •
d
b
b
d
Below is a flowchart showing how to navigate through all
top level menus by pressing the
_____
Underline denotes factory default setup
a
a
a
a
a
a
a
DISPLAY COLOR SETUP (examples)
Example 1:
Output 1 & Output 2: SSR
Alarm setup: Absolute, Above, Alarm 2 HI Value
"ALR.H" =200, Alarm 1 HI Value "ALR.H"=400
Color Display setup: Normal Color "N.CLR"=Green,
Alarm 1 Color "1.CLR"=Amber, Alarm 2 Color "2.CLR"=Red
Display color change sequence:
GREEN |
RED
|
• - ---------------- • ----------------------- • --------------------------------
0
AL2.H=200
AL1.H=400
Example 2:
Output 1: Relay, Set Point 1 = 200,
Output 2: Relay, Set Point 2 = 200
Alarm 1 setup: Deviation, Band, "ALR.H" = 20
Alarm 2 setup: Deviation, Hi/Low, "ALR.H = 10", "ALR.L = 5"
Color Display setup: "N.CLR"=Green, "1.CLR"=Amber,
"2.CLR"=Red
Display color change sequence:
AMBER | RED | GREEN | GREEN | RED | AMBER
• - -------- • ---------- • -------------- • -------------- • ---------- • ------------
0
180
195
200
210
SPECIFICATION
d
a
and
buttons.
Accuracy:
+0.5°C temp;
0.03% rdg. process typical
Resolution:
1°/0.1°; 10 V process
Temperature Stability:
0.04°C/°C RTD;
a
0.05°C/°C TC @ 25°C (77°F);
50 ppm/°C process
Display:
4-digits, 9-segments LED,
21 mm (0.83") with red, green and amber
programmable colors
Input Types:
Thermocouple, RTD, Analog Voltage and
Current
TC:
J, K, T, E, R, S, B, C, N, L
RTD:
100/500/1000 ohm Pt sensor
2-, 3-, or 4-wire; 0.00385 or 0.00392 curve
Input Impedance:
10 M
for 100 mV
1 M
for 1 or 10 Vdc
Voltage:
0 to 100 mV (+50 mV), 0 to 1 V, 0 to 10 Vdc
Current:
0 to 20 mA (5
load)
WARNING: These products are not designed for use in, and should not be used for, patient-
connected applications.
This device is marked with the international caution symbol.
Setup Guide before installing or commissioning this device, as the guide contains important
information relating to safety and EMC.
It is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that apply.
NEWPORT is constantly pursuing certification of its products to the European New Approach Directives.
NEWPORT will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but NEWPORT Electronics, Inc.
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
TRADEMARK NOTICE:
NEWPORT
,
are Trademarks of NEWPORT ELECTRONICS, INC.
WARRANTY/DISCLAIMER
NEWPORT Electronics, Inc. warrants this unit to be free of defects in materials and workmanship for a period of
one (1) year from the date of purchase. In addition to NEWPORT's standard warranty period, NEWPORT
Electronics will extend the warranty period for four (4) additional years if the warranty card enclosed with each
instrument is returned to NEWPORT.
If the unit malfunctions, it must be returned to the factory for evaluation. NEWPORT's Customer Service
Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon
examination by NEWPORT, if the unit is found to be defective, it will be repaired or replaced at no charge.
NEWPORT's WARRANTY does not apply to defects resulting from any action of the purchaser, including but not
limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized
modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows
evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration;
improper specification; misapplication; misuse or other operating conditions outside of NEWPORT's control.
Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
NEWPORT is pleased to offer suggestions on the use of its various products. However, NEWPORT neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result from
the use of its products in accordance with information provided by NEWPORT, either verbal or written.
NEWPORT warrants only that the parts manufactured by it will be as specified and free of defects.
NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,
EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY
DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability
of NEWPORT with respect to this order, whether based on contract, warranty, negligence, indemnification,
strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is
based. In no event shall NEWPORT be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by NEWPORT is not intended to be used, nor shall it be used: (1) as a "Basic
Component" under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical
applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity,
medical application, or used on humans, or misused in any way, NEWPORT assumes no responsibility as set forth
in our basic WARRANTY/DISCLAIMER language, and, additionally purchaser will indemnify NEWPORT and hold
NEWPORT harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a
manner.
RETURN REQUEST/INQUIRIES
AMBER
Direct all warranty and repair requests/inquiries to the NEWPORT Customer Service Department. BEFORE
RETURNING ANY PRODUCT(S) TO NEWPORT, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN
(AR) NUMBER FROM NEWPORT'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package
and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage
in transit.
FOR WARRANTY RETURNS,
please consult NEWPORT for current
repair BEFORE contacting NEWPORT:
1. Purchase Order number under which
the product was PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
NEWPORT's policy is to make running changes, not model changes, whenever an improvement is possible. This
affords our customers the latest in technology and engineering.
NEWPORT is a registered trademark of NEWPORT Electronics, Inc.
© Copyright 2001 NEWPORT Electronics, Inc. All rights reserved.
This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or
machine-readable form, in whole or in part, without the prior written consent of NEWPORT Electronics, Inc.
PATENT NOTICE: This product is covered by one or more of the following patents: U.S. Pat. No. Des. 336,895;
5,274,577; 6,243,021 / Canada 2052599; 2052600 / Italy 1249456; 1250938 / France Brevet No. 91 12756 / Spain
220
2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / Germany DE 41 34398 C2. The ™ is a
Trademark of OMEGA Engineering, Inc. USED UNDER LICENSE. Other U.S. and International patents pending or
applied for.
Output 1:
(Control/Alarm Output)
Relay 250 Vac @ 3 A Resistive Load, SSR,
Pulse, Analog Voltage and Current
Output 2:
(Alarm Output)
Relay 250 Vac @ 3 A Resistive Load, SSR,
Pulse
Output 3:
(Retransmission)
Isolated Analog Voltage and Current
Current: 10 V max @ 20 mA output
Voltage: 20 mA max for 0 - 10 V output
Options: Communication
RS-232 / RS-485 or
Excitation: 24 Vdc @ 25 mA
Not available for Low Power Option
Line Voltage/Power:
90 - 240 Vac ±10%, 50 - 400 Hz*,
or 110 - 375 Vdc, 5 W
* No CE compliance above 60 Hz
Low Voltage Power Option:
20 - 36 Vdc power option, 4 W**
** Units can be powered safely with 24 Vac
but No Certification for CE/UL are claimed.
Dimensions:
48 H x 96 W x 127 D mm
(1.89 x 3.78 x 5")
Weight:
295 g (0.65 lb)
Approvals:
UL, CE per EN50081-1, EN50082-2,
EN61010-1
It is important to read the
®
NEWPORT
®
,
, and the "Meter Bezel Design"
Toll Free: 1-800-639-7678 • http://www.newportUS.com • e-mail:info@newportUS.com
Toll Free: 1-800-639-7678 • http://www.newport.ca • e-mail:sales@newport.ca
Toll Free: 0800 488 488 • http://www.newportuk.co.uk • e-mail:sales@newportuk.co.uk
Toll Free: 0800 0993344 • http://www.newport.nl • e-mail: sales@newport.nl
Toll Free: 0800-1-66342 • http://www.newport.cz • e-mail: sales@newport.cz
Toll Free: 0800 / 6397678 • http://www.newport.de • e-mail: sales@newport.de
FOR NON-WARRANTY REPAIRS,
have the following information available
Toll Free: 0800-4-06342 • http://www.newport.fr • e-mail: sales@newport.fr
charges. Have the following information
available BEFORE contacting NEWPORT:
1. Purchase Order number to cover the
COST the repair,
2. Model and serial number of product,
and
3. Repair instructions and/or specific
problems relative to the product.
MQS3565/N/0701
i/8 Temperature/Process
Controller with Isolated
Analog Output Board
For immediate technical or application assistance please call:
Newport Electronics, Inc.
2229 South Yale Street • Santa Ana, CA • 92704 • U.S.A.
TEL: (714) 540-4914 • FAX: (714) 546-3022
ISO 9001 Certified
Newport Technologies, Inc.
976 Bergar • Laval (Quebec) • H7L 5A1 • Canada
TEL: (514) 335-3183 • FAX: (514) 856-6886
Newport Electronics, Ltd.
One Omega Drive • River Bend Technology Centre
Northbank, Irlam • Manchester M44 5BD • United Kingdom
Tel: +44 161 777 6611 • FAX: +44 161 777 6622
Newport Electronics B.V.
Postbus 8034 • 1180 LA Amstelveen • The Netherlands
TEL: +31 20 3472121 • FAX: +31 20 6434643
Newport Electronics spol s.r.o.
Rudé armády 1868, 733 01 Karviná 8 • Czech Republic
TEL: +420 69 6311899 • FAX: +420 69 6311114
Newport Electronics GmbH
Daimlerstrasse 26 • D-75392 Deckenpfronn • Germany
TEL: 49 7056 9398-0 • FAX: 49 7056 9398-29
Newport Electronique S.A.R.L.
9, rue Denis Papin • 78190 Trappes • France
TEL: +33 130 621 400 • FAX: +33 130 699 120
Mexico and Latin America
TEL: 001-800-826-6342 • FAX: 001 (203) 359-7807
En Español: 001 (203) 359-7803

Advertisement

loading

Summary of Contents for Newport i/8

  • Page 1 Toll Free: 1-800-639-7678 • http://www.newport.ca • e-mail:sales@newport.ca examination by NEWPORT, if the unit is found to be defective, it will be repaired or replaced at no charge. NEWPORT’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 2 Connect the main power connections in the figure shown DISPLAY ABBREVIATIONS This Quick Start Reference provides information Panel Mounting Instruction: below. on setting up your instrument for basic operation. Set Point 1 Value Set Point 2 Value START HERE The latest complete Communication and 1.