Check Grid
Feeding Grid
b. Monitoring Parameter Messages
Operation Condition
Instantaneous Output
Power
Accumulated energy
information
Today's energy
information
Grid Voltage and Current
Grid Frequency
PV Array Voltage and
Current
c. System information Messages
Operation Condition
Model Display
Software version
Waiting for reconnect to
the grid
d. System Fault Messages
Operation Condition
Isolation Failure
Connecting
When PV voltage > 150V, inverter is
xxxS
checking feeding conditions
Working
Inverter is feeding power to the grid
Messages
Descriptions
Pac=
The real time output power in xxxx.xW
xxxx.xW
Energy=
Total energy has been fed to the grid ince
xxxxxxkWh
inverter was installed
Etoday=
Total Energy that has been fed to the grid
xxx.xkWh
today.
AC:xxx.xV
Grid Voltage in xxx.x VAC, feeding urrent
xx.xxA
in xx.xxA
Freq:
Grid frequency in xx.xxHz
xx.xxHz
PV:xxx.xV
Input voltage and current from PV array,
xx.xxA
Messages
Descriptions
EAxKLPV
Inverter Model
vx.xx
Software version
Reconnect
The waiting time for reconnect to the grid
in xxx S
Messages
Descriptions and corrective measure
The resistance between the PV + or PV –
Isolation
and grounding is outside the permissible
Fault
range, <500K.
24>>
Need help?
Do you have a question about the EPIG1K and is the answer not in the manual?