DragonWave Horizon COMPACT Plus Product Manual page 168

Wireless ethernet
Hide thumbs Also See for Horizon COMPACT Plus:
Table of Contents

Advertisement

DragonWave Inc.
160
CLI Command
set radio loopback [on | off] <timeout>
<network>
set radio transmitter state [on | off] [mute
time (seconds)]
set radius server host [index] [server addr]
set radius server key [index] [key]
set
radius
super
user
[On|Off]
set redundancy link monitor parameters
set redundancy link switch parameters
set redundancy mode
set
redundancy
override
secondary | manual | auto ]
set redundancy standby enet state
set redundancy state switch
set rls [on/off] | [basic|advanced]
set rls link control [on/off]
set rls link enable [on/off]
set rls link monitor parameters [mk erred
blks] [brk erred blks] [mk samples] [brk
samples] [mk sample time] [brk sample
time] [brk sample rst time]
set rls make rsl [make rsl threshold] [rsl mk
sample time sec]
set rls port group
Horizon Compact Plus Release 1.0.1
Description
sets the radio loop back[on|off]. If the user doesn't supply
the optional parameter [network], then the modem data
path will be disabled.
allows user to mute/unmute the radio transmitter.
[transmitter state] is enabled or disabled.
sets the host address for server specified by [index].
sets the shared key for server specified by [index].
sets the Radius Authentication Strictness mode. OFF:
authentication
Super User can login using flash password. ON: No one
can login without Radius.
sets redundancy link monitor parameter (both hsb_1wire
and hsb_2wire).
sets redundancy hard error monitor parameter for link
establishing.
allows
[primary_hsb_1wire
primary_hsb_2wire | secondary_hsb_2wire | primary_x2 |
secondary_x2 | normal].
[primary
|
allows the user to set required action on port1 of
primary_hsb_2wire or secondary_hsb_2wire node when it
enters standby state. Allowed actions are 'on', 'off' or
'pulse'.
allows the user to force a change in the redundancy state
when the override mode is 'auto' or 'manual'. The user input
is not stored in the system and set to off after the state
change.
sets the RLS mode on|off and optionally basic|advanced.
sets the RLS user link enable option. When this is set to
'On' the user has to explicitly enable the link after it
recovers from a fault
sets the RLS global link enable status, if on and no link
error exists the link will be enabled.
sets the RLS link monitor low-level parameters
sets the RLS make RSL threshold and sample period,
where: [make rsl threshold]
to establish the link [make rsl sample period]: the time the
link rsl must be above the threshold
establish the link.
enables the user to configure which port or ports are to be
monitored and shut down when an RLS event occurs.
the
user
to
set
|
secondary_hsb_1wire
: the minimum rsl threshold
Wireless Ethernet Product User Manual – Volume 2
system
redundancy
|
to

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Horizon COMPACT Plus and is the answer not in the manual?

Related Products for DragonWave Horizon COMPACT Plus

Table of Contents