5 – FUNCTIONING AND USE
5.3.1

Manual mode activation through the bypass selector switch

The bypass mode can be activated by switching the
selector placed on the right side of the electronic
main box.
NOTE
The bypass mode "on" is advised by the
continuous light of the green led on the START
button.
5.3.2

Preliminary checks before proceeding with the startup procedure

Please, be sure to perform all the following checks before proceeding with the startup procedure:
1. Verify that all plant components are connected correctly.
2. Verify the 5 micron is installed correctly.
3. Be sure the seawater inlet valve and salt water drain valve are opened (If existing).
4. Be sure the reset valve is closed (lever orthogonal to the body valve) and the positioner completely
unscrewed.
5. Be sure the fresh water pressurizing pump of the boat is on.
6. Be sure the valve on the active carbon filter is opened.
7. Be sure the fresh water tank is full enough (at least 100lt) to perform washing procedure.