4 – MOUNTING AND INSTALLATION
The hydraulic connections are:
Low pressure
connections –
max 3 bar
Medium pressure
connections –
max 13 bar
Low pressure
connections -
max 3 bar
PUMP CONNECTIONS:
Connect the in/out hose to the pump as follows:
CAUTION
The pump has to be placed as close as possible to the seawater intake and as low as
possible respect to the seawater level; furthermore, it is recommended to avoid long and
windy path of the connection hoses.
THE PRESENT MANUAL BELONGS TO -
Connection between seawater intake – net
filter – non-return valve inlet – pump group
Connection between the discharge of the
watermaker – through hull discharge fittings of
the vessel
Connections fresh water pressurized system–
carbon filter-backflow valve outlet–pump inlet
Connections
pump outlet-5 microns filter–
watermaker inlet.
Watermaker - fresh water tank
WATERMAKER INTAKE AND DISCHARGE
FIG. 4-2
Schenker Italia
- ALL RIGHTS RESERVED
24
COD.
60M12/24.A.2018
Armorvin rinforced pipe PN6
with 16mm internal diameter
Armorvin rinforced pipe PN6
with 16mm internal diameter
Rubber rinforced pipe PN 16
minimum, internal diameter
16 mm.
¼'' fittings, Small plastic blue
pipe 6x8mm provided within
the scope of supply