5.
Setup a "Benchmark" (page 8).
6.
Install the ceiling grid. Attach the magnetic laser target to the ceiling trim being installed.
Adjust the height of the trim until the laser beam strikes the target.(Fig. 5)
Laydown Applications (3150, 3175)
1.
Place the instrument in the laydown position on a flat, level surface.
2.
Press the (A) button. Allow the instrument to self-level.(Fig. 6)
3.
Setup a "Benchmark" (page 8).

OPERATION

Remove the laser from its carrying case. The instrument is shipped with a battery current
protection insert, which must be removed before operation.
NOTE: All 3100 Series instruments are shipped with ADS on as the default setting. This setting can
be changed by the user (see Anti-Drift System - ADS, page 12).
Note: 3175 instruments will default to Grade Mode when the instrument is turned on. The Mode
button is used for both selecting between the X-axis and Y-axis for setting grade and exiting the
Grade Mode (see Grade Mode — Dual or Single Axis Grade). Press and release the Mode button
to select between the X-axis and Y-axis when setting grade. To exit the Grade Mode, press and
hold the Mode button for 4 to 5 seconds, then release. This will bring up the Mode Select Menu.
The user can now toggle to other menu options. Pressing the Mode button for 4 to 5 seconds and
releasing is only required to exit the Grade Mode.
Leveling
1:
The instrument can stand alone on a level, sturdy surface or preferably secured to a 5⁄8" x 11
surveyor's tripod.
2:
Press the (A) button once, and allow time (up to 60 seconds) for the instrument to self-level.
NOTE: The laser head may begin to rotate before leveling is complete. The self-leveling speed is
approximately 1° per 4 seconds.
3:
After self-leveling, the instrument will begin operating in Rotation Mode. Note: The 3150 will
return to last mode of operation (i.e. sweep, spot, or rotation speed); however, does
not retain grade information.
NOTE: After self-leveling, the instrument will begin operating in Rotation Mode for 3110-GR, last
selected mode of operation (i.e. Sweep, Spot, Rotation Mode) for 3150, and Grade Mode for 3175.
Plumbing / Lay-Down (Models 3150 and 3175)
1.
On a flat surface, place the instrument on its back using the built-in trivet (control panel
facing upward). (Fig. 7)
2.
Press the (A) button once, and allow time for the instrument to self-level.
3100 SERIES • 9