Advertisement

Quick Links

MEET 1L Panel
INSTALLER'S MANUAL
ENGLISH Version
FERMAX ELECTRÓNICA S.A.U.
http://www.fermax.com
Version number: V1.3
 
MEET 1L Panel manual available at
https://www.fermax.com/qr/meet/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEET 1L and is the answer not in the manual?

Questions and answers

Summary of Contents for Fermax MEET 1L

  • Page 1 MEET 1L Panel INSTALLER'S MANUAL ENGLISH Version FERMAX ELECTRÓNICA S.A.U. http://www.fermax.com Version number: V1.3   MEET 1L Panel manual available at https://www.fermax.com/qr/meet/...
  • Page 2 Copyright Notice Fermax and Fermax MEET panel are trademarks of Fermax Electronica S.A.U. registered in the European Union and other countries. © FERMAX ELECTRÓNICA S.A.U., 2018. Page 2...
  • Page 3: Table Of Contents

    INDEX 1   Product Introduction ....................... 4   1.1   Overview ......................... 4   2   Functions Introduction ....................5   2.1   Call Tenant ......................5   2.2   IC Reader (Only panel with proximity reader) ............5   3  ...
  • Page 4: Product Introduction

    1 Product Introduction 1.1 Overview Microphone High definition camera Lighting for night vision with LEDs Speaker Pushbutton for calling IC reader (Only for panel with reader) Slider Page 4...
  • Page 5: Functions Introduction

    2 Functions Introduction  Call tenant  Open door, relay delay settings  Speech message for release lock  Door opened alarm  Tamper alarm  Alarm management by access control (only panel with proximity reader) 2.1 Call Tenant Visitor push the pushbutton for calling in the 1L Panel, the ring back tone will be sent, meanwhile the monitor will ring.
  • Page 6: Configuration Via Web Server

    3 Configuration via Web Server The 1L panel has an integrated web server, allowing for configuration changes. This web server is accessed via the panel’s IP address. The browser opens with the configured IP address of the panel. A screen opens requesting a username and password.
  • Page 7: General Settings

    3.2 General Settings BLOCK: Block number the 1L panel belongs to, between 001 and 999 (default option 1). ROOM: Apartment number with which the 1L panel communicates with, between 0001 and 9899 (default option 101). PANEL NO.: Panel Number, between 1 and 9 (default option 1). TYPE: 1L PANEL.
  • Page 8: Network Settings

    3.3 Network Settings MEET allows the installer to define the IP range according to the projects needs making the network management easier. MEET panel network mode is static mode. Ensure that each device has a unique IP address in same installation. The devices (digital panel, monitor and guard unit) will show IP conflict if there are same IP.
  • Page 9: Acc

    3.4 ACC DOOR RELAY TIME: Time for lock-release relay remains active. DOOR DELAY TIME: The time when the unlocked signal is sent to the start of the relay. The delay time is useful when the lock is not close panel. ADMIN CARD: Master card registered when there is no management software, the card of tenant can be managed by the master card.
  • Page 10: Sip Settings

    3.5 SIP Settings ENABLE SIP: Enable or disable sip function. SIP SERVER: SIP server IP address. DOMAIN: Sip server domain. OUTBOUND: Some servers are used when NAT. STUN IP: Audio and video NAT traversing public network server IP. STUN PORT: The port of audio and video NAT traversing public network server. H.264: Video coding parameters.
  • Page 11: Advance

    3.6 Advance Quick dial is associated a MIO monitor, guard unit or sip terminal. QUICK DIAL: Enable quick dial function or disable. NOTE: The panel type do not use 1L panel if you enable quick dial. URL: if call device of MEET system, URL: sip: sip account @ IP address of MEET device, the sip account is optional.
  • Page 12: Log Out

    3.8 Log Out Log out the web server Page 12...
  • Page 13: Installation

    4 Installation 4.1 Installation height Page 13...
  • Page 14: Installation Step Diagram

    4.2 Installation Step Diagram ○ ○ ○ 1 Flush box install. 2 Base flush box depth adjustment hook. 3 The upper part of the panel is stuck in, then move the panel to the flush box. 1.7CM 1.7CM ○ 4 Move the slider of the panel and fix the two screws, when installing, we should pay attention to the reservation of the 1.7CM space around the door to move the slide cover.
  • Page 15: Connectors

    4.3 Connectors  10/100Mbps RJ45 Port  +,—: 12Vdc Power Input  C,NO,NC: Relay contacts for release lock  BS,—: Exit button  —, SP: Door-open sensor  485+, 485-: RS485 port (spare) Page 15...
  • Page 16: Technical Parameters

    4.4 Technical Parameters Dimensions Panel (mm): 118 (W) × 183(H) × 49(D) Flush box (mm): 105(W) × 172.5(H) × 63(D) Power supply: 12Vdc Standby current: 125mA Working current: 250mA Camera pixel: 1.3 megapixels visual angle: Vertical 72º, Horizontal 54º Minimum illumination: 0.5Lux Maximum conversation time: 120s Door relay time: 1-9s Door delay time: 0-9s...