PlPER AIRCRAFT CORPORATION
PA-28-161, CHEROKEE WARRIOR Il
SUPPLEMENT 4
AIR CONDIDONING INSTALLATION
SECTION 1 - GENERAL
SECTION 9
SUPPLEMENTS
This supplement supplies information necessazy for the efficient operation of the airplane when the
optional air conditioning system is installed. The information contained within this supplement is to be
used "as described" in conjunction with the complete handbook.
This supplement has been "FAA Approved" as
.a
permanent part of this handbook and must remain
in
this handbook at all times when the optional air conditioning system is installed.
SECTION 2- LIMITATIONS
(a)
To insure maximum climb performance the air conditioner must be turned "OFF" manually
prior to takeoff to disengage the compressor and retract the condenser door. Also the air
conditioner must be turned "OFF" manually before the landing a;:iµroach in preparation for a
possible go-around.
(b) Placards
In full view of the pilot, in the area of the air conditioner controls when the air conditioner is
installed:
"WARNING - AIR CONDITIONER MUST BE OFF TO INSURE
NORMAL TAK.EOFF CLIMB PERFORMANCE."
In full view of the pilot, to the right of the engine gauges (condenser door light):
"AIR COND DOOR
OPEN''
SECTION 3 - EMERGENCY PROCEDURES
No changes to the basic Emergency Procedures provided by Section 3 of this Pilot's Operating
Handbook are necessary for this supplement.