Getting Started; Design And Installation Considerations; Fire Safety; Negative Pressure - Quadra-Fire 43M-ACC-NZ Installation Manual

4300 millennium new zealand wood appliance automatic combustion control (acc)
Hide thumbs Also See for 43M-ACC-NZ:
Table of Contents

Advertisement

4300 Millennium NZ Wood Appliance
2

Getting Started

A. Design and Installation Considerations
Consideration must be given to:
Safety
Convenience
Traffic flow
Chimney and chimney connector required
It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation. If you are not
using an existing chimney, place the appliance where there
will be a clear passage for a factory-built listed chimney
through the ceiling and roof.
We recommend that a qualified building inspector and your
insurance company representative review your plans before
and after installation.
If this appliance is in an area where children may be near
it is recommended that you purchase a decorative barrier
to go in front of the appliance. Remember to always keep
children away while it is operating and do not let anyone
operate this appliance unless they are familiar with these
operating instructions.
CAUTION
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult insurance carrier, local building, fire officials
or authorities having jurisdiction about restrictions,
installation inspection, and permits.
WARNING
Asphyxiation Risk.
Do NOT connect this appliance to a
chimney flue servicing another appliance.
Do NOT connect to any air distribution duct
or system.
May allow flue gases to enter the house.
NOTICE
Hearth & Home Technologies assumes no
responsibility for the improper performance of the
appliance system caused by:
Inadequate draft due to environmental conditions
Down drafts
Tight sealing construction of the structure
Mechanical exhausting devices
Over drafting caused by excessive chimney heights
Ideal performance is with height of chimney between
14-16 feet (4.26-4.88m) measured from the base of
the appliance.
4
Install Guide
B. Fire Safety
To provide reasonable fire safety, the following should be
given serious consideration:
1. Install at least one smoke detector on each floor of
2. A conveniently located Class A fire extinguisher to
3. A CO detector should be installed in the room with the
4. A practiced evacuation plan, consisting of at least two
5. A plan to deal with a chimney fire as follows:
6. In the event of a chimney fire:
C. Negative Pressure
Negative pressure results from the imbalance of air
available for the appliance to operate properly. It can be
strongest in lower levels of the house.
Causes include:
7037-181A
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer's placement and installation instructions,
and be sure to maintain regularly.
contend with small fires resulting from burning embers.
appliance.
escape routes.
a. Evacuate the house immediately
b. Notify fire department.
WARNING
Asphyxiation Risk.
Negative pressure can cause spillage
of combustion fumes, soot and carbon
monoxide.
Appliance needs to draft properly for safety.
Exhaust fans (kitchen, bath, etc.)
Range hoods
Combustion air requirements for furnaces, water
appliances and other combustion appliances
Clothes dryers
Location of return-air vents to furnace or air
conditioning
Imbalances of the HVAC air handling system
Upper level air leaks such as:
-
Recessed lighting
-
Attic hatch
-
Duct leaks
16 August, 2018