Amprobe 38XR-A User Manual page 34

Professional digital multimeter
Hide thumbs Also See for 38XR-A:
Table of Contents

Advertisement

Available languages

Available languages

Test Frequency
Overload
protection
TEMPERATURE
Ranges
Resolution
Accuracy
FREQUENCY
Ranges
Resolution
Accuracy
Sensitivity
Minimum input
range
Minimum pluse
width
cycle limits
Overload
protection
1.3 Hz on 40 nF to 40 μF ranges;
0.7 Hz on 400 μF range
1000 V dc or 750 V ac rms
-4 °F to 2372 °F, -20 °C to 1300 °C
(3999 counts)
1 °C, 1 °F
±(2.0 % rdg + 8 °F) -4 °F to 50 °F
±(1.0 % rdg + 6 °F) 50 °F to 400 °F
±(2.0 % rdg +4 °F)400 °F to2372 °F
±(2.0 % rdg +4 °C) -20 °C to 10 °C
±(1.0 % rdg +3 °C)10 °C to 200 °C
±(2.0 % rdg + 2 °C) 200 °C to 1300 °C
100 Hz, 1000 Hz, 10 kHz,
100 kHz, 1000 kHz, 10 MHz,
(auto and manual ranging)
0.1 Hz
±(0.1 % rdg + 5 dgts)
3 Hz to 1 MHz: >1.5 V rms;
1 MHz to 10 MHz: >2 V rms, <5 V rms
100 Hz range >3
Hz 1000 Hz range >30 Hz
> 25 ns Duty
> 30 % and < 70 %
1000 V dc or 750 V ac rms
28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents